background image

Product Overview

The Orchid 

OR-841-HDSDI 

is a single 8.4” fully featured camera-top and field monitor system. The OR-841-

HDSDI offers built-in Waveform Monitor, Vectorscope, Audio Bars, Built In Speaker with audio outputs, and 

several diagnostic tools. This monitor is ideal for use as a camera top or field camera assist monitor. The OR-841-

HDSDI is equipped with two HD/SD-SDI inputs with switched output. Diagnostic tools include our exclusive 

ClipGuide  feature,  16  Tri-Color Audio  Bar  Graph  meters  with  peak  hold  and  numeric  display  of  headroom 

and peak levels, and real-time analysis of color space conversion gamut errors. Other standard features include 

factory calibrated screen, easy-to-navigate onscreen menus with RotoMenu control, 9 assignable function keys,  

adjustable color temperature, aspect ratio settings, a variety of screen markers, blue-only mode, monochrome 

mode, H/V delay, and 7 assignable GPI inputs. 

High Resolution 8.4” Panel 

The OR-841-HDSDI features an all-digital TFT-MegaPixel active matrix LCD system. The LCD panel features 

a nominal brightness of 400 cd/m

2

 and a contrast ratio of 400:1 making each display ideal in a variety of 

environments and lighting conditions. 

Real-time Color Vectorscope

The built-in Vectorscope allows users to monitor color gamut range in real 

time. It displays in full color and can also be displayed in various sizes, 

positions, and transparency options. The Vectorscope has adjustable gain 

from 1x to 5x.

Waveform monitor function

The built-in waveform monitor (which includes adjustable White and Black 

clip level indicators) can be displayed in various aspect ratios, positions, 

and transparency options. The Waveform Monitor not only monitors 

luminance, but can also warn the user for out-of-range conditions such 

as overexposure or “blacker-than-black” errors with fully user-adjustable 

warning limits. 

ClipGuide

The ClipGuide function operates with both the Waveform display and 

Monochrome/Color picture display. Both the upper and lower ClipGuide 

levels are user-adjustable in order to accurately display over-and-under 

exposures during different shooting conditions. For example, the upper 

ClipGuide limit may be set to 85 IRE and the lower limit to 10 IRE. With 

these settings, any exposures over the set limit of 85 IRE will display red 

on both the Waveform and picture (if selected). The same will be true for 

blacks under 10 IRE.

Chroma monitor function

Included in the ClipGuide menu are settings for monitoring color gamut errors, which can occur in color space 

conversion.  Any data exceeding these values will be displayed as Yellow in the picture. The factory preset for C 

limits are 16 and 240 according to ITU-R BT.709. Typically, these values should not be exceeded during normal 

video production.

Features

3

Summary of Contents for ORCHID OR-841-HDSDI

Page 1: ...OR 841 HDSDI Fully Featured 8 4 Rack Mountable Camera Top Portable LCD Field Monitor Operating Instructions Marshall Electronics...

Page 2: ...n 14 Aspect Ratio Setting 14 Mono Color 14 H V Delay 14 Shift H 14 Shift V 15 MARKER CONFIGURATION SUBMENU 15 Markers 15 Center Marker 15 Aspect Markers 15 Safety Marker 15 Marker Mat 15 Line Thicknes...

Page 3: ...ge in real time It displays in full color and can also be displayed in various sizes positions and transparency options The Vectorscope has adjustable gain from 1x to 5x Waveform monitor function The...

Page 4: ...een Markers A variety of screen markers in 4 3 16 9 and full screen modes allow accurate monitoring of the different aspect ratios used in broadcast environments User Definable Function Buttons Nine u...

Page 5: ...threaded mounts There is an optional OR 8RK rack mount kit for mounting two OR 841 HDSDI units side by side in a standard 19 rack When used in this configuration the Dual OR 841 HDSDI units occupy 5...

Page 6: ...Saturation Sharpness Turning the encoder will allow the user to make adjustments to the selected mode ROTOMENU Control Press the ROTOMENU Encoder to access the on screen Menu Turn the encoder to the L...

Page 7: ...ources supplying at least 1 Amp at 12 Volts IMPORTANT If using a power source other than the included power supply be sure that the polarity of the DC input is correct Pin 1 GND Pin 2 N C Pin 3 N C Pi...

Page 8: ...ble Formats 8 Format HD SD SDI 480 60i 576 50i 480 60p 576 50p 720 60p 720 50p 720 30p 720 25 720 24p 1080 60p 1080 50p 1080 60i 30PsF 1080 50i 25PsF 1080 48i 24Psf 1080 30p 1080 25p 1080 24p VGA SVGA...

Page 9: ...CAL D65 CAL D93 RED BIAS 128 to 127 0 is Calibrated Setting GREEN BIAS 128 to 127 0 is Calibrated Setting BLUE BIAS 128 to 127 0 is Calibrated Setting RED GAIN 0 000 to 1 992 x1 00 is Calibrated sett...

Page 10: ...L MEDIUM LARGE POSITION LEFT TOP LEFT BOTTOM RIGHT TO RIGHT BOTTOM TYPE OVERLAY OVERLAP Y OVER LIMIT 100 0 IRE 0 to 109 1 Y UNDER LIMIT 100 0 IRE 7 3 to 109 1 VECTORSCOPE RETURN LAYOUT NORMAL LAYOUT A...

Page 11: ...SATURATION SHARPNESS REMOTE RETURN PIN 1 THRU 8 Pin 5 is Ground INPUT 1 INPUT 2 GAMMA 1 0 GAMMA 1 8 GAMMA 2 0 GAMMA 2 2 GAMMA 2 4 GAMMA 2 6 WHITEBLANCE D65 WHITEBALANCE D93 MONO SCAN ASPECT ZOOM HV DE...

Page 12: ...Main Menu and Navigation Step through menu items by using the RotoMenu control Choose a submenu or select a menu item by pushing the RotoMenu control Return to the previous menu by pressing the F 9 bu...

Page 13: ...panese D93 White Point x 0 2830 y 0 2980 USER Adjustable Color Bias and Gain CAL D65 D93 CAL D65 CAL D93 RGB Bias and Gain Select this submenu to fine tune the monitor s color balance R G B or execute...

Page 14: ...ng the remainder of the screen regardless of its original format In 16 9 mode images are scaled to fill the maximum 16 9 portion of the screen 1024 x 576 regardless of its original format Mono Color U...

Page 15: ...ettings to superimpose one of 6 markers on the screen when in 16 9 mode 4 3 16 9 1 85 1 2 35 1 4 3 and 1 85 1 4 3 and 2 35 1 Safety Marker Use this setting to adjust the safety marker from 80 to 100 O...

Page 16: ...justs the point at which the level meters will change color from Green to Yellow This is normally the level used for alignment For digital audio in the US the SMPTE standard is 20dBFS 0VU 4dBu The Eur...

Page 17: ...occupy on the screen when in the Normal mode Choices are Left Top Left Bottom Right Top and Right Bottom Display Type Use this menu to choose how to display the waveform The choices are Overlay or Ove...

Page 18: ...aque and will block the source video Gain Use this menu to change the gain of the Vectorscope display Normally the Vectorscope displays x1 00 In order to allow a magnified view the gain is adjustable...

Page 19: ...SIGN SUBMENU F 1 thru F 9 There are nine Function Keys and One Rotary Encoder on the front panel of the OR 841 HDSDI Each of these F keys key may be assigned any one of 31 different functions as requi...

Page 20: ...Mix Red and Green for Amber Cannot mix R G B for White It will be pink due to white balance Cannot be assigned with separated tallies Left Right Separated Mode Supports R G B tallies on each Left and...

Page 21: ...r or White Balance Data Requires Confirm action by selecting Confirm again Select Reset RotoMenu control Select Confirm Press RotoMenu control Resetting default will not effect backed up data Backup U...

Page 22: ...o 40 C RoHs Do not dispose Return to Manufacturer or Authorized Recycle Facility PANEL VIDEO INPUT OUTPUT HD SD SDI Video Input Output CONNECTORS Video Input 2 x BNC Female 75 Video Output Active Loop...

Page 23: ...s by using the recommended cleaning and polishing practice Color Calibration Procedure Allow both the unit you want to calibrate and the Minolta CA 210 to warm up for a minimum of 20 minutes Attach th...

Page 24: ...tions or modifications in design or construction void this warranty It is considered normal for a minimal amount of pixels not to exceed three to fail on the periphery of the display active viewing ar...

Reviews: