background image

 

PH10 (Phantom 10) Series 

Unheated 
Model Lengths 36” – 144”  

 
 

14716 S. BROADWAY, GARDENA, CA 90248 ● Ph: (310)532

-1555 Fax: (310)-532-

3030 ● 

www.marsair.com

 

© Copyright Mars Air Systems, LLC 2014 

 

NOTE: MARS AIR SYSTEMS, LLC reserves the right to change specifications and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions or replacements 
for previously purchased equipment. 

MARS AIR SYSTEMS, LLC 

● 

GARDENA, CA 

● 

USA 

Note: Models PH1060-2 & PH1064-2 & PH10120-4 are not AMCA 
Certified. 
The AMCA Certified Ratings Seal applies to airflow rate, average 
outlet velocity, outlet velocity uniformity, velocity projection and power 
rating at free delivery only. 

MARS Air Systems, LLC certifies that the Air Curtains 
shown on this data sheet are licensed to bear the AMCA 
seal. The ratings shown are based on tests and 
procedures performed in accordance with AMCA 
Publication 211 and comply with the requirements of the 
AMCA Certified Ratings Program. 

PH10

Series: Phantom 10

72 2 U A PW

LENGTH OF UNIT

# OF MOTORS

U = UNHEATED

VOLTAGE CODE

COLOR

EXAMPLE

  

   

      

 

 

   

 

   

  

   

 

 

 

   

  

   

  

 

 

 

   

    

 

  

 

 

PH10

(Phantom 10)

Model Number

Nozzle Length

(in)

Length

(in)

Depth

(in)

Height

(in)

Motor

(hp)

Weight

(lbs)

Max Core 

Velocity at 

Nozzle (fpm)

Avg Velocity

(fpm)

Volume

(cfm)

Uniformity

(%)

Power Rating

(watts)

PH1036-1U*-PW

36

36

26

17

1/2

60

3950

1947

1460

91

460

PH1042-1U*-PW

42

42

26

17

1/2

60

4150

1806

1580

89

500

PH1048-1U*-PW

48

48

26

17

1/2

65

3895

1632

1632

91

520

PH1060-2U*-PW

60

60

26

17

Two 1/2

100

3750

2217

2771

93

870

PH1072-2U*-PW

72

72

26

17

Two 1/2

105

3950

1947

2920

91

920

PH1084-2U*-PW

84

84

26

17

Two 1/2

125

4150

1806

3160

89

1000

PH1096-2U*-PW

96

96

26

17

Two 1/2

130

3895

1632

3264

91

1040

PH10108-3U*-PW

108

108

26

17

Three 1/2

170

3950

1947

4380

91

1380

PH10120-4U*-PW

120

120

26

17

Four 1/2

200

3750

2217

5541

93

1730

PH10144-4U*-PW

144

144

26

17

Four 1/2

210

3950

1947

5840

91

1840

Mechanical Data

Note: Data above for 1725 RPM at 60 Hz, 50 Hz is 1425 RPM with a 17% reduction in 
the performance data.

* - Use corresponding letters in "Electrical Data" columns to complete the model numbers.

AMCA Certified Lab Data

Model

Distance from nozzel 

(in)

Avg. Core Velocity 

(FPM)

40

1089

80

1000

120

900

160

822

Projection Velocity

PH1036-1U*

Unheated Data Sheet 

 Applications: Environmental Separation up to 12’ and Insect Control up to 10’

 

1. The AMCA Certified Ratings Seal applies to airflow rate, average outlet velocity, outlet velocity uniformity, velocity projection and power rating at free delivery only. 

2. Rated data shown are only for base (unheated) units, as shown. 

 

Features:  

 

1/2 HP Continuous Duty TEAO Motors 

 

Recessed mounted in ceiling for invisible coverage 

 

AMCA Certified to AMCA 211 (see table above for models available) 

 

ETL Certified to conform to UL 507 (US) and CSA 22.2 (Canada) Standards 

 

Utilized in premium design concepts 

 

Durable aluminum construction 

 

Cabinet has sufficient strength for fastening to wall on both ends without intermediate 

support. (Tandem mounted units longer than 72” require center support)  

 

Cleanable polyester filters included as standard 

 

Adjustable air directional vanes with 40° sweep front to back 

 

Standard color is Pearl White 

 

Rust preventative electrostatic polyurethane powder coating 

 

5 year parts warranty 

 

Freight Included (FOB Continental USA) 

 

Proudly Made in the USA 

 

Options and Accessories: (see Accessories Brochure) 

 

Motor Control Panels 

 

Wall and Overhead Bracket 

 

Multi-speed motors and controls 

 

Aluminum or throwaway pleated filters 

 

Custom colors and finishes (304SS, 316SS) 

 

Noise reduction package

 

 

 

Sound Levels: (measured at 10’ in an open field) 

 

1 Motor Unit = 66 dBA, 2 Motor Unit = 68 dBA, 3 Motor Unit = 71 dBA & 4 Motor Unit = 73 dBA 

 
 

PH10U-B; August 14 2018 

115v

(A)

208/230v/1Ø

(D)

208/230v/3Ø

(G)

460v/3Ø

(H)

575v/3Ø

(I)

PH1036-1U*-PW

5.1

2.5

1.8/1.6

0.8

0.7

PH1042-1U*-PW

5.1

2.5

1.8/1.6

0.8

0.7

PH1048-1U*-PW

5.1

2.5

1.8/1.6

0.8

0.7

PH1060-2U*-PW

10.2

5.0

3.6/3.2

1.6

1.4

PH1072-2U*-PW

10.2

5.0

3.6/3.2

1.6

1.4

PH1084-2U*-PW

10.2

5.0

3.6/3.2

1.6

1.4

PH1096-2U*-PW

10.2

5.0

3.6/3.2

1.6

1.4

PH10108-3U*-PW

15.3

7.5

5.4/4.8

2.4

2.1

PH10120-4U*-PW

20.4

10.0

7.2/6.4

3.2

2.8

PH10144-4U*-PW

20.4

10.0

7.2/6.4

3.2

2.8

Note: For Ampacity Multiply FLA X 1.25

* - Use corresponding letters in "Electrical Data" columns to complete the 
model numbers.

Unit Voltage 

(Voltage Code)

Electrical Data 

(FLA)

Summary of Contents for PH10 Unheated Series

Page 1: ...ithout notice Such revisions do not entitle the buyer to corresponding changes improvements additions or replacements for previously purchased equipment MARS AIR SYSTEMS LLC GARDENA CA USA PH10 Unheat...

Page 2: ...notice Such revisions do not entitle the buyer to corresponding changes improvements additions or replacements for previously purchased equipment MARS AIR SYSTEMS LLC GARDENA CA USA Table of Contents...

Page 3: ......

Page 4: ...lumns to complete the model numbers AMCA Certified Lab Data Model Distance from nozzel in Avg Core Velocity FPM 40 1089 80 1000 120 900 160 822 Projection Velocity PH1036 1U Unheated Data Sheet Applic...

Page 5: ......

Page 6: ...oor type door limit switch installation FIG 1 2 Use light gauge materials when field fabricating brackets to activate and deactivate the door limit switch s FIG 2 Figure 2 also shows the typical insta...

Page 7: ...nded Wall Mounting For Tandem Mounting of air curtain over sectional style door use either wall mounting angle brackets or threaded rods 4 Top Mounting Brackets For overhead installation of units use...

Page 8: ...ies are 1 2 HP and 1 HP respectively The Phantom Series come standard with an air intake screen s GENERAL SAFETY INFORMATION Use this product only in the manner intended by the manufacturer If you hav...

Page 9: ...e screen can be removed from the unit by pulling the spring loaded piano hinges FIG 1 3 All Phantom series have the Motor Fan Assembly MFA shipped internally mounted 4 All units are equipped with 4 3...

Page 10: ...connected in accordance to National Electrical Code and wired per the enclosed wiring diagram For electric heated models ensure that the coils are secured and not touching each other on any metal surf...

Page 11: ...he outdoor elements Contact factory for special construction and costing Freezer and Cooler Installation Air curtain must be mounted on the warm side for optimal performance Variable Frequency Drive V...

Page 12: ...in this manual Obstruction on intake or discharge Remove obstruction or move air curtain Power leads out of polarity Switch power leads to correct polarity 3 phase models only Blower motor rotating be...

Page 13: ...esponsible for transportation charges associated with replacement of failed part Mars does not warrant uninterrupted or error free operation of Mars product Under no circumstance is Mars liable for an...

Page 14: ...g Metal Studs D Section 07900 Joint Sealers E Section 08110 Steel Doors and Frames F Section 08330 Overhead Coiling Doors G Section 15145 Plumbing Piping Gas piping to units H Section 15182 Hydronic P...

Page 15: ...1 Standard for Fixed and Location Dedicated Electric Room Heaters Intertek Testing Services Listed for US and Canada I CSA 3812 01 Fans and Blowers Certified to US Standards Canadian Standard Associat...

Page 16: ...tions trouble shooting guide parts list and electrical wiring diagrams 1 5 QUALITY ASSURANCE A Manufacturer Qualifications Minimum ten years documented experience producing the products specified in t...

Page 17: ...2 AIR CURTAIN ASSEMBLIES A Motor Fan Assembly Design for easy removal assembly repair and maintenance 1 Motor Totally enclosed air over TEAO cooled motor with sealed lifetime pre lubricated ball bear...

Page 18: ...ghts to 10 feet 3048 mm 1 Discharge Nozzle Wedge shaped discharge outlet nozzle with adjustable air foil vanes with a plus minus 40 degree sweep front to back 2 Air Velocity at Nozzle a PH10 36 1 36 I...

Page 19: ...ized steel bolted to air curtain housing 8 Supply and return fittings on ends of casing 9 Thermostat Wall mounted 110 Volt operation with heater on off selection C Hot Water Heaters Provide finned tub...

Page 20: ...trol panel Provide a separate control panel for three phase motors controlled by a limit switch 1 Type Combination plunger roller switch for swing and sliding doors a Provide limit switches with NEMA...

Page 21: ...st air curtains to function properly B Adjust air foil vanes located within the discharge nozzle as required for prevailing conditions at each opening C Check heated air curtain performance on a calm...

Page 22: ...ing changes improvements additions or replacements for previously purchased equipment MARS AIR SYSTEMS LLC GARDENA CA USA Reference Links Link Description http marsair com Main website http marsair co...

Reviews: