WARRANTY 
 

Mars’  warranty  coverage,  period,  extent  and 
limitations  apply  to  the  product  only.    It  does  not 
apply to labor.  Mars warrants that Mars product 1) 
Is  free  from  defects  in  materials  and  workmanship 
and  2) Conforms  to  Mars’  published  specifications.  
The warranty period for Mars product except heated 
and  custom  models,  is  a  five  (5)  year  period 
commencing  on  its  date  of  shipment.    The  date  on 
customer’s  invoice  is  the  date  of  shipment,  unless 
Mars  or  your  reseller  informs  you  and  Mars 
otherwise.    For  heated  products,  the  warranty 
period  is  an  eighteen  (18)  month  period  and  for 
custom  products  and  accessories,  the  warranty 
period  is  twelve  (12)  months  period  commencing 
the  date  of  shipment.  Mars  will  provide  free 
replacement  of  any  part  that  fails  as  a  result  of  a 
defect  in  material  or  manufacturer’s  workmanship.  
Changes  in  operational  specification  parameters 
that are different from those provided on the original 
purchase  order  are  not  covered.    Mars  product  is 
inspected  and  tested  before  packaging  and  is 
shipped  in  working  condition.    The  warranty  for 
Mars 

product 

only 

covers 

free-of-charge 

replacement of failed parts.  The warranty does not 
cover  labor  and  transportation  expenses  that  may 
be  required  to  provide  and  to  install  replacement 
parts.    Because  in  many  instances,  it  is  impossible 
to determine the cause of failure, customer may be 
responsible  for  transportation  charges  associated 
with  replacement  of  failed  part.    Mars  does  not 
warrant  uninterrupted  or  error-free  operation  of 
Mars product.  Under no circumstance is Mars liable 
for  any  of  the  following:  1)  Third-party  claims 
against  you  for  damages;  or  2)  Special,  incidental, 
or  indirect  damages  or  for  any  economic 
consequential  damages  (including  lost  profits  and 
savings), even if Mars, its suppliers, or its reseller is 
informed of their possibility.  The warranty does not 
cover  repair  or  exchange  of  Mars  product  resulting 
from  misuse,  accident,  modification,  unsuitable 
physical  or  operating  environment,  improper 
maintenance and installation by customer, or failure 
caused  by  a  product  for  which  Mars  is  not 
responsible.  The warranty does not cover damages 
caused  by  mishandling  during  transportation.    The 
warranty is voided by removal or alteration of Mars 
product  or  parts  identification  labels,  by  improper 
installation of product, and resulting non-compliance 
to  federal,  state  and  local  codes  and  regulations.  
Additionally,  Mars  reserves  the  right  to  void  the 
warranty for non-payment of invoice. 

 
CONTACT FACTORY FOR COMPLETE PARTS 
LIST FOR ALL MODELS. 
 
KEEP THIS MANUAL FOR YOUR RECORDS. 
 
 

 

Model Number: _____________________________ 

Serial Number: _____________________________ 

Date Purchased: ____________________________ 

Dealer Purchased From:______________________ 

 

 

 

 

 

 

 

 

 

 

14716 S. Broadway St., Gardena, CA 90248 

(310) 532

–1555 ● (800) 421-1266 

Fax: (310) 324-3030 

Please go to our website at 

www.marsair.com

 for a 

downloadable version of this document. 

Summary of Contents for PH10 Unheated Series

Page 1: ...ithout notice Such revisions do not entitle the buyer to corresponding changes improvements additions or replacements for previously purchased equipment MARS AIR SYSTEMS LLC GARDENA CA USA PH10 Unheat...

Page 2: ...notice Such revisions do not entitle the buyer to corresponding changes improvements additions or replacements for previously purchased equipment MARS AIR SYSTEMS LLC GARDENA CA USA Table of Contents...

Page 3: ......

Page 4: ...lumns to complete the model numbers AMCA Certified Lab Data Model Distance from nozzel in Avg Core Velocity FPM 40 1089 80 1000 120 900 160 822 Projection Velocity PH1036 1U Unheated Data Sheet Applic...

Page 5: ......

Page 6: ...oor type door limit switch installation FIG 1 2 Use light gauge materials when field fabricating brackets to activate and deactivate the door limit switch s FIG 2 Figure 2 also shows the typical insta...

Page 7: ...nded Wall Mounting For Tandem Mounting of air curtain over sectional style door use either wall mounting angle brackets or threaded rods 4 Top Mounting Brackets For overhead installation of units use...

Page 8: ...ies are 1 2 HP and 1 HP respectively The Phantom Series come standard with an air intake screen s GENERAL SAFETY INFORMATION Use this product only in the manner intended by the manufacturer If you hav...

Page 9: ...e screen can be removed from the unit by pulling the spring loaded piano hinges FIG 1 3 All Phantom series have the Motor Fan Assembly MFA shipped internally mounted 4 All units are equipped with 4 3...

Page 10: ...connected in accordance to National Electrical Code and wired per the enclosed wiring diagram For electric heated models ensure that the coils are secured and not touching each other on any metal surf...

Page 11: ...he outdoor elements Contact factory for special construction and costing Freezer and Cooler Installation Air curtain must be mounted on the warm side for optimal performance Variable Frequency Drive V...

Page 12: ...in this manual Obstruction on intake or discharge Remove obstruction or move air curtain Power leads out of polarity Switch power leads to correct polarity 3 phase models only Blower motor rotating be...

Page 13: ...esponsible for transportation charges associated with replacement of failed part Mars does not warrant uninterrupted or error free operation of Mars product Under no circumstance is Mars liable for an...

Page 14: ...g Metal Studs D Section 07900 Joint Sealers E Section 08110 Steel Doors and Frames F Section 08330 Overhead Coiling Doors G Section 15145 Plumbing Piping Gas piping to units H Section 15182 Hydronic P...

Page 15: ...1 Standard for Fixed and Location Dedicated Electric Room Heaters Intertek Testing Services Listed for US and Canada I CSA 3812 01 Fans and Blowers Certified to US Standards Canadian Standard Associat...

Page 16: ...tions trouble shooting guide parts list and electrical wiring diagrams 1 5 QUALITY ASSURANCE A Manufacturer Qualifications Minimum ten years documented experience producing the products specified in t...

Page 17: ...2 AIR CURTAIN ASSEMBLIES A Motor Fan Assembly Design for easy removal assembly repair and maintenance 1 Motor Totally enclosed air over TEAO cooled motor with sealed lifetime pre lubricated ball bear...

Page 18: ...ghts to 10 feet 3048 mm 1 Discharge Nozzle Wedge shaped discharge outlet nozzle with adjustable air foil vanes with a plus minus 40 degree sweep front to back 2 Air Velocity at Nozzle a PH10 36 1 36 I...

Page 19: ...ized steel bolted to air curtain housing 8 Supply and return fittings on ends of casing 9 Thermostat Wall mounted 110 Volt operation with heater on off selection C Hot Water Heaters Provide finned tub...

Page 20: ...trol panel Provide a separate control panel for three phase motors controlled by a limit switch 1 Type Combination plunger roller switch for swing and sliding doors a Provide limit switches with NEMA...

Page 21: ...st air curtains to function properly B Adjust air foil vanes located within the discharge nozzle as required for prevailing conditions at each opening C Check heated air curtain performance on a calm...

Page 22: ...ing changes improvements additions or replacements for previously purchased equipment MARS AIR SYSTEMS LLC GARDENA CA USA Reference Links Link Description http marsair com Main website http marsair co...

Reviews: