background image

 

TROUBLESHOOTING 

 

 

 

PROBLEM 

CAUSE 

SOLUTION 

NO AIR BLOWING 
OUT OF DISCHARGE 
NOZZLE 

- No power being supplied to the unit  

from the electrical power source 

 - Confirm power source / check if in on position 

  

 - Circuit breaker is tripped 

 - Reset circuit breaker 

  

 - Blown fuses on power supply  

 - Replace fuses 

  

 - Motor overload is open or tripped 

 - Allow the motor to cool down; motor has auto reset 

internal overload; if unit is panel equipped, press 
reset button on overload inside panel, or replace 
motor overload if overload remains tripped 

  

 - Motor contactor / relay defective  

(if applicable) 

 - Check voltage to coil; check contacts to see if they 

are pulling in 

  

 - Failed switch 

 - Replace or repair limit switch 

MOTOR IS RUNNING 
BUT FANS ARE NOT 
SPINNING 

 - Loose or broken coupling (belt drive) 

 - Replace or tighten coupling 

  

 - Loose set screws on wheel hubs 

 - Tighten set screws on motor shaft flats 

  

 - Fan spinning inside fan housing 

 - Tighten fan on shaft or replace fan 

  

 - Broken fan hub 

 - Replace fan wheels 

ELECTRICAL 
CONTROLS NOT 
WORKING WHEN 
DOOR IS OPEN 

 - Switch is in off position 

 - Turn unit's switch to the on position 

  

 - Door limit switch is not operating 

 - Repair or replace door limit switch 

UNIT WILL NOT TURN 
OFF 

 - Door limit switch is permanently 

closed or energized 

 - Position the door switch in a manner that turns off the 

unit when the door closes, and turns on the unit when 
the door opens.  Only light pressure required. 

LOW AIR FLOW 

 - Discharge air vanes out of 

adjustment 

 - Adjust vanes to proper position                            

(Refer to Start-Up Section in this manual) 

  

 - Obstruction on intake or discharge 

 - Remove obstruction or move air curtain  

  

 - Power leads out of polarity                                       

 - Switch power leads to correct polarity                                            

(3 phase models only) 

  

 - Blower motor rotating below normal 

speed 

 - Apply proper voltage per unit requirement                  

(see unit label) / Adjust adjustable motor speed knob 
(if applicable) 

  

 - Fan rubbing against housing 

 - Free fan from housing 

  

 - Blower wheels clogged with dirt 

 - Clean and remove dirt from blower wheels 

EXCESSIVE AIR 
VELOCITY AT DOOR 
OPENING 

 - Nozzle out of adjustment and not 

angled far out enough (BD only) 

 - Adjust nozzle angle to outside 

  

 - Air temperature too cold 

 - Add auxiliary heat to overcome wind chill 

  

 - Air stream pushing air outside of the 

building 

 - Adjust discharge angle back into building 

  

 

  

AIR NOT HITTING 
THE FLOOR 

 -  Low air velocity  

 - Adjust vanes to proper position or check installation 

height (Refer to Start-Up Section in this manual) 

  

 -  Obstruction in the direction of air flow 

 - Remove obstruction or move air curtain                                                                

(Move out 3/8" for every 1" up from the door) 

  

 -  Negative building pressure 

 - Provide a make-up air system to relieve negative 

building pressure 

UNEVEN AIR 

 - Shaft rotating inside fan 

 - Replace fan or tighten fan on shaft 

  

 - One motor not functioning 

 - Replace or repair motor 

EXCESSIVE NOISE 
AND OR VIBRATION 

 - Loose or broken coupling (belt drive) 

 - Replace or tighten coupling 

  

 - Loose set screws on wheel hubs 

 - Tighten set screws on motor shaft flats 

  

 - Fan spinning inside fan housing 

 - Tighten fan on shaft or replace fan 

  

 - Broken fan hub 

 - Replace fan wheels 

  

 - Bearing end caps worn 

 - Replace Bearing end caps 

  

 - Damaged blower wheel 

 - Replace Blower Wheel 

  

 - Bearing end caps worn 

 - Replace Bearing end caps 

  

 - Balancing clips missing 

 - Replace Blower Wheel 

 

Summary of Contents for PH10 Unheated Series

Page 1: ...ithout notice Such revisions do not entitle the buyer to corresponding changes improvements additions or replacements for previously purchased equipment MARS AIR SYSTEMS LLC GARDENA CA USA PH10 Unheat...

Page 2: ...notice Such revisions do not entitle the buyer to corresponding changes improvements additions or replacements for previously purchased equipment MARS AIR SYSTEMS LLC GARDENA CA USA Table of Contents...

Page 3: ......

Page 4: ...lumns to complete the model numbers AMCA Certified Lab Data Model Distance from nozzel in Avg Core Velocity FPM 40 1089 80 1000 120 900 160 822 Projection Velocity PH1036 1U Unheated Data Sheet Applic...

Page 5: ......

Page 6: ...oor type door limit switch installation FIG 1 2 Use light gauge materials when field fabricating brackets to activate and deactivate the door limit switch s FIG 2 Figure 2 also shows the typical insta...

Page 7: ...nded Wall Mounting For Tandem Mounting of air curtain over sectional style door use either wall mounting angle brackets or threaded rods 4 Top Mounting Brackets For overhead installation of units use...

Page 8: ...ies are 1 2 HP and 1 HP respectively The Phantom Series come standard with an air intake screen s GENERAL SAFETY INFORMATION Use this product only in the manner intended by the manufacturer If you hav...

Page 9: ...e screen can be removed from the unit by pulling the spring loaded piano hinges FIG 1 3 All Phantom series have the Motor Fan Assembly MFA shipped internally mounted 4 All units are equipped with 4 3...

Page 10: ...connected in accordance to National Electrical Code and wired per the enclosed wiring diagram For electric heated models ensure that the coils are secured and not touching each other on any metal surf...

Page 11: ...he outdoor elements Contact factory for special construction and costing Freezer and Cooler Installation Air curtain must be mounted on the warm side for optimal performance Variable Frequency Drive V...

Page 12: ...in this manual Obstruction on intake or discharge Remove obstruction or move air curtain Power leads out of polarity Switch power leads to correct polarity 3 phase models only Blower motor rotating be...

Page 13: ...esponsible for transportation charges associated with replacement of failed part Mars does not warrant uninterrupted or error free operation of Mars product Under no circumstance is Mars liable for an...

Page 14: ...g Metal Studs D Section 07900 Joint Sealers E Section 08110 Steel Doors and Frames F Section 08330 Overhead Coiling Doors G Section 15145 Plumbing Piping Gas piping to units H Section 15182 Hydronic P...

Page 15: ...1 Standard for Fixed and Location Dedicated Electric Room Heaters Intertek Testing Services Listed for US and Canada I CSA 3812 01 Fans and Blowers Certified to US Standards Canadian Standard Associat...

Page 16: ...tions trouble shooting guide parts list and electrical wiring diagrams 1 5 QUALITY ASSURANCE A Manufacturer Qualifications Minimum ten years documented experience producing the products specified in t...

Page 17: ...2 AIR CURTAIN ASSEMBLIES A Motor Fan Assembly Design for easy removal assembly repair and maintenance 1 Motor Totally enclosed air over TEAO cooled motor with sealed lifetime pre lubricated ball bear...

Page 18: ...ghts to 10 feet 3048 mm 1 Discharge Nozzle Wedge shaped discharge outlet nozzle with adjustable air foil vanes with a plus minus 40 degree sweep front to back 2 Air Velocity at Nozzle a PH10 36 1 36 I...

Page 19: ...ized steel bolted to air curtain housing 8 Supply and return fittings on ends of casing 9 Thermostat Wall mounted 110 Volt operation with heater on off selection C Hot Water Heaters Provide finned tub...

Page 20: ...trol panel Provide a separate control panel for three phase motors controlled by a limit switch 1 Type Combination plunger roller switch for swing and sliding doors a Provide limit switches with NEMA...

Page 21: ...st air curtains to function properly B Adjust air foil vanes located within the discharge nozzle as required for prevailing conditions at each opening C Check heated air curtain performance on a calm...

Page 22: ...ing changes improvements additions or replacements for previously purchased equipment MARS AIR SYSTEMS LLC GARDENA CA USA Reference Links Link Description http marsair com Main website http marsair co...

Reviews: