DaNgEr
DO NOT HANG THE END OF THE SHORE POWER CORD INTO THE WATER. NEARbY SWIMMERS OR PASSENGERS CAN
bE KILLED OR SERIOUSLY INJURED FROM THE SURROUNDING ELECTRICAL FIELD.
DaNgEr
DEATH OR SERIOUS INJURY MAY INCUR bY INCORRECTLY SERVICING THE AC ELECTRICAL SYSTEM. ONLY TRAINED
ELECTRICIANS SHOULD SERVICE THE YACHT’S AC ELECTRICAL SYSTEM.
bEFORE ATTEMPTING TO SERVICE THE AC ELECTRICAL SYSTEM, ALWAYS:
DISCONNECT THE YACHT FROM THE SHORE POWER SOURCE
•
SHUT OFF THE GENERATOR
•
DISAbLE THE INVERTER
•
SHORE POWER CONNECTION
SHORE POWER CONNECTION PROCESS:
sTEP 1:
Switch OFF the Water Heater circuit breaker, located on the AC BUS 1 Distribution Panel, in the Engine Room
Aft .
DO NOT
switch the breaker ON again until the fresh water system has been filled, pressurized, and primed .
sTEP 2:
Switch OFF both SHORE and GENERATOR circuit breaker groups, located on the AC BUS 1 Distribution Panel,
in the Engine Room Aft .
sTEP 3:
Switch OFF the AC MAIN circuit breaker group(s),
located on the AC BUS 1 Distribution Panel and AC BUS 2
Distribution Panel, in the Engine Room Aft .
NOTE:
Switch off the AC MAIN circuit breakers before connecting to the shore power to prevent arch
ing and burning of the shore power cord receptacles . Disconnecting will protect the electrical
equipment on board from rapid ON/OFF current connections, which may occur during the con
nection process .
sTEP 4:
Locate the 50’ shore power cord . Connect the female end of the cord to the yacht’s shore power receptacle,
located at the PORT Aft Stairway .
sTEP 5:
Connect the female end of the cord(s) to the yacht’s shore power receptacles(s) . The receptacles(s) are
located
on the PORT transom
.
If the optional forward shore power receptacle(s) are equipped, they are
located on the
STDB forward side deck .
sTEP 6:
Secure the nonmetallic threaded locking ring to the yacht’s shore power receptacle . Securing, prevents the cord
from being accidentally disconnected, and prevents arcing due to a gap between the cord plug and the receptacle .
sTEP 7:
Unthread the access cap and lift cap up . Pay out cord as needed using the Cable Master Switch .
sTEP 8:
Switch the External Cord and Cablemaster circuit breaker OFF, installed in the source box at the shore power
station,
located in the Engine Room Aft STBD
.
sTEP 9:
Plug the male end of the shore power cord into the shore power source outlet .
sTEP 10:
Secure the nonmetallic threaded locking ring to the shore power source outlet . Securing the locking ring prevents
the cord from being accidentally disconnected and from arcing due to a gap between the cord plug and the
outlet .
7027 • A2 07/11
32
aC e
leCTriCal
s
YsTem
s
eCTion
3
Summary of Contents for 720 FLY
Page 1: ...HIN CDR__________________ 2012 Version 1 Marquis 720 FL Y Owner s Guide...
Page 2: ......
Page 4: ......
Page 6: ...Table of Contents 7027 A2 07 11 Lower Helm Components...
Page 7: ...Preface 7027 A2 07 11 i Bridge Helm Controls...
Page 10: ...Preface iv 7027 A2 07 11 PAGE INTENTIONALLY LEFT BLANK...
Page 41: ...7027 A2 07 11 29 DC Electrical System Section 2...
Page 42: ...30 7027 A2 07 11 DC Electrical System Section 2 PAGE INTENTIONALLY LEFT BLANK...
Page 56: ...PAGE INTENTIONALLY LEFT BLANK 7027 A2 07 11 44 AC Electrical System Section 3...
Page 59: ...Air conditioning system Stateroom deck 7027 A2 07 11 47 Internal System Section 4...
Page 62: ...Internal water system 50 7027 A2 07 11 Internal System Section 4...
Page 86: ...74 7027 A2 07 11 Propulsion Section 5 PAGE INTENTIONALLY LEFT BLANK...
Page 120: ...108 7027 A2 07 11 Warranty and Parts Section 9 Thru Hull Fittings...
Page 121: ...7027 A2 07 11 109 Warranty and Parts Section 9 Thru Hull Fittings...
Page 122: ...110 7027 A2 07 11 Warranty and Parts Section 9 Bill of Materials...
Page 123: ...7027 A2 07 11 111 Warranty and Parts Section 9 Marquis Limited Warranty...