![MARLO MATD 9500 XT Manual Download Page 67](http://html.mh-extra.com/html/marlo/matd-9500-xt/matd-9500-xt_manual_1729699067.webp)
8
•
Flooded suction mounting (installing the pump at the base of the chemical
storage tank, Figure 4) is the most trouble free type of installation and is
recommended for very low output requirements. Since the suction tubing is
filled with chemical, priming is accomplished quickly and the chance of losing
prime is reduced.
To mount pump, drill four holes of .25” (6 mm) diameter in the shelf as shown in
the dimension drawing (Figure 2). Attach pump securely using four #10 (M5) bolts
and nuts.
FIGURE 2
5.5.3 4-20mA DC INPUT FUNCTION cont'd.
•
The signal cord polarity is:
Black
=
Common
White =
Positive
Wrong polarity can result in excess flow.
Signal input impedance is 124 ohms.
Remove cap from pump socket labeled 4-20 mA, use polarized cord supplied
with pump to connect control circuit to pump. Plug cord into pump socket
labeled 4-20 mA.
6.0 MAINTENANCE
Before performing any maintenance or repairs on chemical
metering pumps, be sure to disconnect all electrical connec-
tions, insure that all pressure valves are shut off and pressure
in the pump and lines has been bled off.
Always wear protective clothing, gloves and safety glasses when
performing any maintenance or repairs on chemical metering
pumps.
6.1 ROUTINE MAINTENANCE
•
Routinely check the physical operating condition of the pump. Look for the
presence of any abnormal noise, excessive vibration, low flow and pressure
output or high temperatures [when running constantly at maximum stroke
rate, the pump housing temperature can be up to 160
°
F (70
°
C)].
•
For optimum performance, cartridge valves should be changed every 6-12
months. Depending on the application, more frequent changes may be
required. Actual operating experience is the best guide in this situation.
•
Repeated short-term deterioration of valve seats and balls usually indicates
a need to review the suitability of wetted materials selected for the applica-
tion. Contact the supplier for guidance.
•
Check for leaks around fitting or as a result of deteriorating tubing e.g. when
standard white translucent discharge tubing is exposed to direct sunlight.
Take appropriate action to correct leak by tightening fittings or replacing
components.
•
Keep the pump free of dirt and debris as this provides insulation and can lead
to excessive pump temperatures.
17
FIG. 5
FIG. 4
FIG. 3
•
The pump can be mounted on
top of a solution tank as shown
in Figure 5. Install chemical pump
on the cover. Insert suction tub-
ing through the center hole and
cut tubing so foot valve/strainer
hangs about 1 or 2 inches (2-5
cm) above the bottom of the tank.
Mount the chemical pump rig-
idly by drilling four .25” (6 mm)
holes and using four #10 (M5)
screws and nuts.
•
USE AN ANTI-SIPHON VALVE IN THE DISCHARGE LINE whenever the
fluid pressure in the discharge line is below atmospheric pressure. This can
occur if the injection point is on the suction side of a water pump or against
a "negative" head such as when feeding down into a well.
Summary of Contents for MATD 9500 XT
Page 4: ......
Page 7: ...9500 Control Dimensions Page 4 MATD 9500 XT MANUAL ...
Page 11: ...Page 8 ...
Page 19: ...Page 16 WATER CONDITIONER FLOW DIAGRAMS MATD 9500 XT MANUAL ...
Page 20: ...Page 17 WATER CONDITIONER FLOW DIAGRAMS MATD 9500 XT MANUAL ...
Page 21: ...Page 18 WATER CONDITIONER FLOW DIAGRAMS MATD 9500 XT MANUAL ...
Page 40: ...9500 Power Head Assy 61501 3200XT 9_REVA Page 37 MATD 9500 XT MANUAL ...
Page 42: ...9500XT Wiring 42140_2750XT_2850XT_REVA 0_2750XT_2850XT_REVA Page 39 MATD 9500 XT MANUAL ...
Page 43: ...Page 40 9100 9500 MATD 9500 XT MANUAL ...
Page 44: ...Page 41 9500 MATD 9500 XT MANUAL ...
Page 45: ...Page 42 9500 Control Valve Assembly MATD 9500 XT MANUAL ...
Page 46: ...Page 43 Second Tank Assemblies MATD 9500 XT MANUAL ...
Page 47: ...Page 44 Second Tank Assemblies MATD 9500 XT MANUAL ...
Page 48: ...Page 45 Meter Assemblies MATD 9500 XT MANUAL ...
Page 49: ...Page 46 Meter Assemblies MATD 9500 XT MANUAL ...
Page 50: ...Page 47 3 4 1 or 1 1 2 Paddle Wheel Meter Cap Assembly MATD 9500 XT MANUAL ...
Page 51: ...Page 48 Brine Valve Systems 1600 and 1700 Series MATD 9500 XT MANUAL ...
Page 52: ...Page 49 9500 2350 Safety Brine Valve MATD 9500 XT MANUAL ...
Page 53: ...Page 50 ...
Page 54: ...Page 51 Troubleshooting MATD 9500 XT MANUAL ...