Page 1
5
SALT and CAUSTIC REGENERATION
Steps 1 - 3 are the same in this calculation.
4. From the capacity chart Figure 2 for Ionac ASB-2 using 50% alkalinity and 400 TDS the
capacity is approximately 8 kgr / cu.ft.
This should be downgraded by 10% 8 kg-r x .9 = 7.2 kgr / cu.ft. 5.
5. To calculate the throughput capacity
(7.2 kgr x 1000) / 11.7 = 615 gallons / cu.ft.
6. Leakage will be approximately 10 % of the influent alkalinity, 20 ppm CO, or HCO
3
as CaCO
3
.
The calculation to determine total carbonate alkalinity leakage when caustic soda is used as
part of the regenerant is as follows:
2 x P alkalinity
=
Carbonate present
MO alkalinity - (2 x P alkalinity) =
Bicarbonate present
Carbonate alk. + Bicarbonate alk. =
Total Carbonate Alkalinity Leakage
For immediate regeneration type meter control the meter setting would be at 15,000 gallons.
Commonly this value is adjusted to 90 percent of the actual value (in this example 13,500
gallons) to assure not over-running the softener.
For time delay type meters the amount of gallons is determined as in our example except an
additional amount of gallons must be deducted from the actual gallons to allow soft water to be
available until the softener regenerates at he selected delay time of day or night. This
compensation is necessary since the meter will indicate regeneration-required time prior to the
set delay time.
Summary of Contents for MATD 9500 XT
Page 4: ......
Page 7: ...9500 Control Dimensions Page 4 MATD 9500 XT MANUAL ...
Page 11: ...Page 8 ...
Page 19: ...Page 16 WATER CONDITIONER FLOW DIAGRAMS MATD 9500 XT MANUAL ...
Page 20: ...Page 17 WATER CONDITIONER FLOW DIAGRAMS MATD 9500 XT MANUAL ...
Page 21: ...Page 18 WATER CONDITIONER FLOW DIAGRAMS MATD 9500 XT MANUAL ...
Page 40: ...9500 Power Head Assy 61501 3200XT 9_REVA Page 37 MATD 9500 XT MANUAL ...
Page 42: ...9500XT Wiring 42140_2750XT_2850XT_REVA 0_2750XT_2850XT_REVA Page 39 MATD 9500 XT MANUAL ...
Page 43: ...Page 40 9100 9500 MATD 9500 XT MANUAL ...
Page 44: ...Page 41 9500 MATD 9500 XT MANUAL ...
Page 45: ...Page 42 9500 Control Valve Assembly MATD 9500 XT MANUAL ...
Page 46: ...Page 43 Second Tank Assemblies MATD 9500 XT MANUAL ...
Page 47: ...Page 44 Second Tank Assemblies MATD 9500 XT MANUAL ...
Page 48: ...Page 45 Meter Assemblies MATD 9500 XT MANUAL ...
Page 49: ...Page 46 Meter Assemblies MATD 9500 XT MANUAL ...
Page 50: ...Page 47 3 4 1 or 1 1 2 Paddle Wheel Meter Cap Assembly MATD 9500 XT MANUAL ...
Page 51: ...Page 48 Brine Valve Systems 1600 and 1700 Series MATD 9500 XT MANUAL ...
Page 52: ...Page 49 9500 2350 Safety Brine Valve MATD 9500 XT MANUAL ...
Page 53: ...Page 50 ...
Page 54: ...Page 51 Troubleshooting MATD 9500 XT MANUAL ...