![Maritime Geothermal TF-45 Installation And Service Manual Download Page 5](http://html.mh-extra.com/html/maritime-geothermal/tf-45/tf-45_installation-and-service-manual_1727434005.webp)
1-Jul-2017
Page 5
001223MAN-05
Tables & Documents
Table 1 - Power Supply Connections (Heat Pump) ................................................................................. 6
Table 2 - Power Supply Connections (Optional Plenum Heater) ............................................................. 6
Table 3 - Air Thermostat Signal Description ............................................................................................ 7
Table 4 - Aquastat Signal Description ...................................................................................................... 7
Table 5 - Typical Aquastat Settings .......................................................................................................... 7
Table 6 - Airflow Selections ..................................................................................................................... 8
Table 7 - Control Board Fault Codes ..................................................................................................... 10
Table 8 - Heat Pump Size vs. Heated Area for a Ground Loop System ................................................ 17
Table 9 - Heat Pump Size vs. Heated Area for an Open Loop System ................................................. 17
Table 10 - Heat Pump Size vs. Hot Air Grills ......................................................................................... 18
Table 11 - Plenum Heater Sizing ........................................................................................................... 18
Table 12 - Duct Sizing Guide ................................................................................................................. 21
Table 13 - Antifreeze Percentages ........................................................................................................ 29
Table 14 - Volume of Fluid per 100ft. Of Pipe ....................................................................................... 29
Table 15 - Required Flow ...................................................................................................................... 35
Table 16 - Refrigerant Charge Chart ..................................................................................................... 60
Table 17 - Shipping Information ............................................................................................................. 60
Table 18 - Operating Temperature Limits ............................................................................................... 60
Table 19 - Standard Capacity Ratings - Ground Loop Heating 60Hz .................................................... 60
Table 20 - Standard Capacity Ratings - Ground Water Heating 60Hz ................................................... 60
Table 21 - Standard Capacity Ratings - Ground Loop Cooling 60Hz .................................................... 61
Table 22 - Standard Capacity Ratings - Ground Water Cooling 60Hz ................................................... 61
Table 23 - Standard Capacity Ratings - Ground Loop Hydronic Heating 60Hz ..................................... 61
Table 24 - Standard Capacity Ratings - Ground Water Hydronic Heating 60Hz ................................... 61
Table 25 - Open Loop Pressure Drop Data ........................................................................................... 62
Table 26 - Closed Loop Pressure Drop Data ......................................................................................... 62
Table 27 - MED Airflow (nominal) ........................................................................................................... 71
Table 28 - LOW Airflow (-6%) ................................................................................................................. 71
Table 29 - HIGH Airflow (+6%) ............................................................................................................... 71
Table 30 - MAX Airflow (+12%) .............................................................................................................. 71
Table 31 - Heat Pump Electrical Information (208/230-1-60) ................................................................ 72
Table 32 - Heat Pump Electrical Information (208-3-60) ........................................................................ 72
Table 33 - Heat Pump Electrical Information (460-3-60) ....................................................................... 72
Table 34 - Heat Pump Electrical Information (220-1-50) ....................................................................... 72
Table 35 - Heat Pump Electrical Information (380-3-50) ....................................................................... 72
Table 36 - Plenum Heater Electrical Information (208/230-1-60) .......................................................... 73
001827CDG - Typical Thermostat Connections .................................................................................... 12
001224CDG - TF Series: Two Stage Aquastat Connection Diagram ..................................................... 13
000344CDG - Typical Heating Only Zone Wiring ................................................................................... 14
001901PDG - Wiring For Best Cooling Mode Dehumidification ............................................................ 15
000970PDG - Single Unit Connection to DHW Pre-Heat Tank ............................................................. 16
001915INF - Internal Plenum Heater Installation .................................................................................... 19
002222PDG - Typical Duct and Condensate Connections - TF Series .................................................. 20
002238PDG - Typical Loop Connections - TF Series ............................................................................. 23
001046PDG - Typical Buffer Tank Configuration: Four Port Tank .......................................................... 24
001981PDG - Typical Buffer Tank Configuration: Two Port Tank .......................................................... 25
000530PDG - Typical Zone Types for Hydronic Applications ................................................................. 26
001055PDG - Single Unit Connection to On-Demand DHW Pre-Heat Tank .......................................... 27
000608INF - Typical Horizontal Ground Loop Configuration .................................................................. 30
000609INF - Typical Vertical Ground Loop Configuration ...................................................................... 31
000906CDG - Geo-Flo Circulator Pump Module Installation ................................................................. 32
001823CDG - Dual Flow Circulator Pump Module Installation for 2-Stage Heat Pumps ........................ 33
000629PDG - Circulator Pump Module Installation - Two Units on One Ground Loop........................... 34
000907CDG - Typical Ground Water (Open Loop) Installation ............................................................. 38
001822CDG - Dual Flow Groundwater (Open Loop) Installation for 2-Stage Heat Pumps ................... 39
000619INF - Ground Water Disposal Methods ...................................................................................... 40
001453SCH - TF Series Schematic Diagram 208/230-1-60 .................................................................. 74
001454ELB - TF Series Electrical Box Diagram 208/230-1-60 .............................................................. 75
001610SCH - TF Series Schematic Diagram 208-3-60 ......................................................................... 76
001611ELB - TF Series Electrical Box Diagram 208-3-60 ..................................................................... 77
002223SCH - TF Series Schematic Diagram 460-3-60 .......................................................................... 78
002224ELB - TF Series Electrical Box Diagram 460-3-60 ...................................................................... 79
001447SCH - TF Series Schematic Diagram 220-1-50 .......................................................................... 80
001448ELB - TF Series Electrical Box Diagram 220-1-50 ...................................................................... 81
001197RCD - TF Series Refrigeration Circuit - Air Heating Mode ......................................................... 82
001198RCD - TF Series Refrigeration Circuit - Air Cooling Mode ......................................................... 83
001199RCD - TF Series Refrigeration Circuit - Hydronic Heating Mode ............................................... 84
Tables
Documents
Summary of Contents for TF-45
Page 12: ...Page 12 001223MAN 05 1 Jul 2017 ...
Page 13: ...1 Jul 2017 Page 13 001223MAN 05 ...
Page 14: ...Page 14 001223MAN 05 1 Jul 2017 ...
Page 15: ...1 Jul 2017 Page 15 001223MAN 05 ...
Page 16: ...Page 16 001223MAN 05 1 Jul 2017 ...
Page 19: ...1 Jul 2017 Page 19 001223MAN 05 ...
Page 20: ...Page 20 001223MAN 05 1 Jul 2017 ...
Page 23: ...1 Jul 2017 Page 23 001223MAN 05 ...
Page 24: ...Page 24 001223MAN 05 1 Jul 2017 ...
Page 25: ...1 Jul 2017 Page 25 001223MAN 05 ...
Page 26: ...Page 26 001223MAN 05 1 Jul 2017 ...
Page 27: ...1 Jul 2017 Page 27 001223MAN 05 ...
Page 30: ...Page 30 001223MAN 05 1 Jul 2017 ...
Page 31: ...1 Jul 2017 Page 31 001223MAN 05 ...
Page 32: ...Page 32 001223MAN 05 1 Jul 2017 ...
Page 33: ...1 Jul 2017 Page 33 001223MAN 05 ...
Page 34: ...Page 34 001223MAN 05 1 Jul 2017 ...
Page 38: ...Page 38 001223MAN 05 1 Jul 2017 ...
Page 39: ...1 Jul 2017 Page 39 001223MAN 05 ...
Page 40: ...Page 40 001223MAN 05 1 Jul 2017 ...
Page 74: ...Page 74 001223MAN 05 1 Jul 2017 Wiring Diagram 208 230 1 60 ...
Page 75: ...1 Jul 2017 Page 75 001223MAN 05 Electrical Box Layout 208 230 1 60 ...
Page 76: ...Page 76 001223MAN 05 1 Jul 2017 Wiring Diagram 208 3 60 ...
Page 77: ...1 Jul 2017 Page 77 001223MAN 05 Electrical Box Layout 208 3 60 ...
Page 78: ...Page 78 001223MAN 05 1 Jul 2017 Wiring Diagram 460 3 60 ...
Page 79: ...1 Jul 2017 Page 79 001223MAN 05 Electrical Box Layout 460 3 60 ...
Page 80: ...Page 80 001223MAN 05 1 Jul 2017 Wiring Diagram 220 1 50 ...
Page 81: ...1 Jul 2017 Page 81 001223MAN 05 Electrical Box Layout 220 1 50 ...
Page 82: ...Page 82 001223MAN 05 1 Jul 2017 ...
Page 83: ...1 Jul 2017 Page 83 001223MAN 05 ...
Page 84: ...Page 84 001223MAN 05 1 Jul 2017 ...
Page 85: ...1 Jul 2017 Page 85 001223MAN 05 Dimensions TF 45 Left Return ...
Page 86: ...Page 86 001223MAN 05 1 Jul 2017 Dimensions TF 45 Right Return ...
Page 87: ...1 Jul 2017 Page 87 001223MAN 05 Dimensions TF 55 65 75 80 Left Return ...
Page 88: ...Page 88 001223MAN 05 1 Jul 2017 Dimensions TF 55 65 75 80 Right Return ...