44
Command to read current temperature:
ATTN
ADDR
CMD0
CMD1
CMD2
LEN
IHCHK DATA IDCHK
0x07
0xFF
0x54
0x4D
0x50
0x01
0x07
0x52
0xAD
Acknowledge current temperature:
ATTN
ADDR
CMD0
CMD1
CMD2
LEN
IHCHK DATA
DATA
0x06
0xFF
0x54
0x4D
0x50
0x06
0x03
0x2B
0x30
DATA
DATA
DATA
DATA IDCHK
0x34
0x32
0x2E
0x35
0xDB
Request Type/Model Number (TYP) INPUT:
This command shall be sent to the display to read its model number. No data shall be sent
with this command.
If the data checksum is valid the display shall reply to this command with an ACK attention
code. The data field shall be an ASCII string, fifteen bytes maximum, to indicate the model
number i.e. MPC-MI19.
Command to read Type/model number:
ATTN
ADDR
CMD0
CMD1
CMD2
LEN
IHCHK
0x07
0xFF
0x54
0x59
0x50
0x00
0xFC
Acknowledge Type/model number:
ATTN
ADDR
CMD0
CMD1
CMD2
LEN
IHCHK
O
m
0x06
0xFF
0x54
0x59
0x50
0x0F
0xEE
0x4F
0x6D
e
g
a
sp
M
F
P
1
9
sp
0x65
0x67
0x61
0x20
0x4D
0x46
0x50
0x31
0x39
0x20
sp
sp
sp
IDCHK
0x20
0x20
0x20
0x2A