11
INSTALLATION
General Installation and Mounting Instructions
General Installation and Mounting
•
Our displays are designed for various installation mountings (panel mounting, bracket
mounting and VESA mounting). For details please see our installation drawings.
•
When mounting the display in a confined area, i.e. console, adequate ventilation must
be provided to limit the maximum temperature to 55°C.
•
The distance of each electronics unit from the magnetic standard compass or the
magnetic steering compass must not be less than the permitted safe compass distance
of the device. See the safe compass distance later in this section.
•
The maximum cable lengths must not exceed the recommended industry
recommended lengths.
•
The display must be properly grounded. A short wide cable (braid) gives the best
results.
•
For ECDIS applications, the calculated nominal recommended viewing distance is
1,013 mm. (IEC62288, Part 7.5 Screen resolution).
Mounting Instructions
The display can be mounted to a custom mounting bracket (not supplied), panel mounted
or VESA mounted. The following is a list the required mounting hardware (not supplied):
Panel mounting
x4 - 6.2mm Dia. holes left and right sides
Panel mounting
x4 – m6 inserts on rear top and bottom
VESA mounting
x4 – m4 inserts on rear cover
Bracket mounting
x8 – m6 inserts, 4 per side on rear cover