(15) The location of water treatment equipment (chlorinator, ozonizer, etc.) has
a major impact on the service life of the heat pump. Such a disinfection dosing
device must be located so that the dosing outlet is located behind the heat
pump. This part of the line requires at least a siphon between the heat pump
and the chlorinator to prevent water backflow.
5. ELECTRICAL CONNECTION
IMPORTANT: The heat pump is supplied with a supply cable fitted with
a plug for connection to a socket. The installation of the socket must
comply with the requirements of ČSN 33 2000, including adequate
protection and the use of a current protector with a tripping current of
up to 30 mA.
The heat pump together with the power supply of the filter unit pump must, if
possible, be connected via a separate circuit breaker and switch, or a timer for
regular commissioning. The supply must be sufficiently dimensioned and equipped
with a current protector with a tripping current of up to 30 mA. Electrical network
characteristics (voltage and frequency) including the fuse must correspond to the
operating parameters of the device.