73
EN
TECHNICAL DATA
Note: The values for heating output and operating power input may differ depen-
ding on the climatic and operating conditions.
Heating Ambient air temperature: 27/24 °C, temperature of supply water: 26°C
Ambient air temperature: 15/14 °C, temperature of supply water: 26°C
Operating range: Ambient temperature: 10 – 43 °C
Water temperature: 15 – 44 °
PREMIUM 3500
Basic parameters:
Heating output
Ambient
temperature
(dry/wet)
27°C / 24°C*
(kW)
3,5
Btu/h
11900
COP, (operating)
-
Rated power input
(kW)
Heating output
15°C / 12°C*
(kW)
Btu/h
COP, (operating)
-
Rated power input
(kW)
Electrical parameters
Power supply
(V~ / Hz)
230~/50Hz
Protection level
-
IPX4
Protection class
-
I
Parameters of pool installation
Recommended pool capacity
(m
3
)
<15
Minimum water flow through the exchanger
(m
3
/h)
Connecting dimension
mm
32
General parameters
Exchanger
-
titanium and PVC
Compressor
-
1 x rotating
Airflow direction
-
horizontal
Fan speed
(1/min)
700
Fan power consumption
(W)
25
Noise level
(dB(A))
Water pressure drop
kPa
1.2
Refrigerant (heat transfer fluid)
-
R32
Refrigerant charge weight
(kg)
0.25
Net weight
(kg)
27
Overall dimensions (L x D x H)
(mm)
420 x 375 x 420
4,86
0,72
46
1,5
2,63
8942
3,70
0,71