MarelliMotori M40FA640A/A Mark I User Manual Download Page 11

 

 

963857132_I

 

 

10 

1. INTRODUCTION 

 
This  User  Manual  provides  general  installation  and  use  information  regarding  the  Marelli  Motori  regulator  whose  code  is 
reported on the cover and inside the document, mounted on Marelli Motori generator types indicated in Chap. 3.  
Before  starting  the  generator  and  performing  any  type  of  regulation  operation,  carefully  and  completely  read  all  of  the 
instructions contained in this manual. 
 
IMPORTANT  NOTE:  This  User  Manual  not  intended  to  cover  all  of  the  possible  application  or  installation  variations  nor  to 
provide  data  or  information  to  support  every  possible  contingency.  The  connection  diagrams  provided  with  the  generator,  its 
Use  and  Maintenance  Manual  and  any  additional  information  provided  by  qualified  Marelli  Motori  technical  personnel 
supplements and completes this manual.  
In  particular,  the  diagrams  reported  in  this  document  provide  only  an  example  of  the  connection  and  operation  mode  for  the 
device; these do not cover all possible application cases and are not a substitute for the connection diagrams normally provi ded 
with the generator. 
 
If further application information becomes necessary, please contact Marelli Service, whose contact data is shown below. 

 

 
AFTER MARKET DEPARTMENT 
MARELLI MOTORI S.p.A. 
Tel:  

+39 0444 479775 

Fax:  

+39 0444 479757 

E-mail:  

[email protected]

 

Web:  

www.marellimotori.com

 

2. SAFETY PRECAUTIONS 

 

 

ATTENTION: DO NOT TOUCH THE CONTROL MODULE WHEN IT IS UNDER POWER. 
When  the  control  module  is  under  power  (or  the  machine  is  in  rotation)  the  upper part  of  the  device 
(connection  side)  and  all  parts  electrically  connected  to  it  contain  lethal  voltage.

  There  could  be  also 

components with high temperatures that are dangerous in the event of direct contact during normal operation 
on the component module. 

 

 
 
 

Any  operation  on  the  cabling  and/or  mechanical  installation  of  the  regulator  must  be  performed  by 
qualified and informed personnel, with the generator halted and making sure that a sufficient amount 
of  time  has  passed  for  the  regulator  components  to  have  cooled  down  to  a  temperature  that  is  not 
dangerous to personal safety. 
 

 

Each  calibration  operation  must  be  performed  with  the  machine  running  without  a  load  by  qualified 
and  informed  personnel  using  the  proper  tools  to  guarantee  electrical  safety  (for  example,  insulated 
screwdrivers) and wearing all of the necessary personal safety devices (especially safety glasses and 
protective gloves). 
 

Marelli Motori denies any responsibility for damage to the regulator, system or people, for loss of profit or money, or for system 
shutdowns caused by the failure to observe the safety and/or installation/use instructions reported in this User Manual. 

3. APPLICATION 

 
The voltage regulator type M40FA640A/A - MARK I is suitable for Synchronous Generators of MARELLI  MOTORI make, MJB 
series, size range 160-500 frames. The regulator is proper both for single and 3-phase generators. 
NOTE:  For  information  on  compatibility  with  different  sizes  or  series  of  synchronous  generators  other  than  those  indicated 
above, contact Marelli Service. 
 
 

 

Summary of Contents for M40FA640A/A Mark I

Page 1: ...e Synchronous Generator G n rateur Synchrones Triphas s Drei Phasen Synchrongeneratoren Generadores S ncronos Tr fasicos M40FA640A A Mark I Regolatore di tensione Automatic voltage regulator R gulateu...

Page 2: ...963857132_I 1 Revision history Rev Description Date First release 11 2013 H Ex SIN NT 015 11 03 2016 I New contact list page 43 09 2016...

Page 3: ...963857132_I 2 Italiano pagina 3 English page 10 Fran ais page 17 Deutsch seite 24 Espa ol p gina 31 Drawings page 38...

Page 4: ...NDO ESSA E ALIMENTATA Quando la scheda di regolazione alimentata ovvero con macchina in rotazione presente una tensione letale per l uomo sulla parte superiore del dispositivo lato connessioni e su tu...

Page 5: ...Resistenza di campo 3 20 Precisione di regolazione da vuoto a carico Da 0 a 100 del carico nominale PF 0 8 carico bilanciato e non distorcente frequenza costante 0 5 Precisione di regolazione a regim...

Page 6: ...z frequenza minore di 45Hz detta frequenza di corner Togliendo il ponticello normalmente presente tra i terminali Hz e 60 la protezione per bassi giri agisce in modo appropriato per funzionamento a 60...

Page 7: ...corrente di eccitazione qualora il generatore sia utilizzato a bassa velocit per evitare danni al sistema di eccitazione del generatore cio al regolatore o al circuito di campo principale al ponte ra...

Page 8: ...venire al superamento di una soglia di tensione di eccitazione di circa il 15 20 superiore a quella che si ha in condizioni di massimo carico desiderato Il tempo di intervento dipendente dall eventual...

Page 9: ...sso analogico porre estrema attenzione al valore assunto dall ingresso analogico al momento dell uscita dal parallelo Affinch il generatore non si trovi in una condizione di pericolosa sovratensione l...

Page 10: ...sull applicazione finale con il generatore 15 MANUTENZIONE La sola manutenzione preventiva richiesta per il regolatore il controllo delle connessioni tra il regolatore stesso e il sistema assicurarsi...

Page 11: ...IS UNDER POWER When the control module is under power or the machine is in rotation the upper part of the device connection side and all parts electrically connected to it contain lethal voltage Ther...

Page 12: ...eld voltage 100 Vdc Field resistance 3 20 Regulation accuracy from no load to full load From 0 to 100 of the rated load PF 0 8 balanced and non deforming load constant frequency 0 5 Steady state accur...

Page 13: ...tory in order to reduce the excitation when speed becomes lower than 90 of rated speed at 50 Hz frequency lower than 45 Hz or corner frequency By removing the bridge which normally shorts the terminal...

Page 14: ...avoid damages to the excitation system of the generator i e to the regulator to the exciter field to the rotating rectifier main rotor The potentiometer FREQ fixes the corner frequency that is the fre...

Page 15: ...d in the voltage regulator to allow parallel operation between similar generators the device permits to share correctly the total reactive power required by the load among all generators operating in...

Page 16: ...8 must be reduced to 0 V or to any values leading to a generator voltage not exceeding the rated 5 11 FUSE The voltage regulator is provided with an internal protecting fuse which acts in case of faul...

Page 17: ...final generator application 15 MAINTENANCE The only preventative maintenance required for the regulator is to check the connections between the regulator itself and the system make sure they are clea...

Page 18: ...ELLE EST SOUS ALIMENTATION Quand la carte de r glage est branch e c est dire quand la machine est en rotation il existe une tension mortelle pour l homme sur la partie sup rieure du dispositif c t co...

Page 19: ...ximum de champ 100 Vdc R sistance de champ 3 20 Pr cision de r gulation de 0 100 charge De 0 100 charge nominal PF 0 8 charge quilibr e et lin aire fr quence constante 0 5 R gime permanent fr quence e...

Page 20: ...fr quence de coupure Si l on enl ve le pont normalement pr sent entre les terminaux Hz et 60 la protection pour les bas r gimes de tours agit de mani re ad quate pour un fonctionnement 60 Hz Tournez...

Page 21: ...rent la r duction du courant d excitation si le g n rateur est utilis vitesse faible pour viter des dommages au syst me d excitation du g n rateur c est dire au r gulateur ou au circuit de champ prin...

Page 22: ...assement d un seuil de tension d excitation d environ 15 20 sup rieur celui qu on a en conditions de charge d sir e maximale Le temps d intervention d pend de l ventuelle surcharge n cessaire et peut...

Page 23: ...ogique pr ter une attention extr me la valeur prise par l entr e analogique au moment de la sortie du parall le Afin que le g n rateur ne se trouve pas en condition de surtension dangereuse la tension...

Page 24: ...avec le g n rateur 15 ENTRETIEN Le seul entretien pr ventif requis par le r gulateur est le contr le des connexions entre le r gulateur et le syst me assurez vous que celles ci soient propres et soud...

Page 25: ...KARTE BER HREN WENN SIE MIT STROM VERSORGT WIRD Wenn die Reglerkarte mit Strom versorgt wird das hei t wenn die Maschine sich dreht besteht auf der oberen Fl che des Ger tes Anschlussseite und an alle...

Page 26: ...ldwiderstand 3 20 Pr zisionseinstellung von 0 bis 100 Ladung Von 0 bis 100 Ladung PF 0 8 balanced and non deforming load constant frequency 0 5 Steady state Bei konstanter Frequenz und Ladung 0 1 Accu...

Page 27: ...man die Br cke die sich normalerweise zwischen den Klemmen Hz und 60 befindet wird die Schutzvorrichtung entsprechend eines Betriebes mit 60 Hz aktiviert setzt der Schutz f r niedrige Umdrehungen Um...

Page 28: ...n den Erregerstrom wenn der Generator bei geringer Geschwindigkeit eingesetzt wird damit Sch den am Erregungssystem des Generators vermieden werden bzw am Regler am Gleichrichter am Rotor Mit dem Pote...

Page 29: ...ellt dass sie aktiviert wird sobald die Schwelle der Erregungsspannung ungef hr 15 20 ber dem Wert bei normaler gew nschter Belastung liegt Die Aktivierungszeit h ngt von der eventuellen notwendigen b...

Page 30: ...durch den Analogeingang beim Verlassen der Parallele angenommen wird zu achten Damit der Generator nicht der Gefahr der berspannung ausgesetzt wird muss die Spannung auf den Klemmen 6 und 8 auf den W...

Page 31: ...e finale Anwendung mit Generator gepr ft werden 15 WARTUNG Die Anschl sse zwischen dem Regler und dem System m ssen regelm ig kontrolliert werden Sie m ssen sauber sein und fest sitzen Die Verkabelung...

Page 32: ...DO ES ALIMENTADA Cuando la tarjeta de regulaci n es alimentada o bien con la m quina en rotaci n est presente una tensi n letal para el hombre en la parte superior del dispositivo lado de conexiones y...

Page 33: ...5 Adc Tensi n de campo m xima 100 Vdc Resistencia de campo 3 20 Precisi n de regulaci n de 0 a 100 carga De 0 a 100 carga PF 0 8 carga equilibrada y lineal frecuencia constante 0 5 Estado estable frec...

Page 34: ...ncia inferior a 45Hz denominada frecuencia l mite Quitando el puente generalmente presente entre los terminales Hz y 60 la protecci n para baja velocidad act a de modo adecuado para funcionamiento a 6...

Page 35: ...ue se encargan de reducir la corriente de excitaci n cuando el generador se utilice a velocidades bajas para evitar provocar da os en el sistema de excitaci n del generador es decir en el regulador o...

Page 36: ...ere un l mite de tensi n de excitaci n de aproximadamente un 15 20 superior a la que existe en condiciones de carga m xima deseada El tiempo de intervenci n depende de la posible sobrecarga y puede va...

Page 37: ...nal gica preste la m xima atenci n al valor que adquiere la entrada anal gica al salir de la conexi n en paralelo Para evitar que el generador alcance un peligroso estado de sobretensi n la tensi n en...

Page 38: ...NIMIENTO El nico mantenimiento preventivo necesario para el regulador es la comprobaci n de las conexiones entre el regulador mismo y el sistema hay que asegurarse de que estas est n limpias y firmes...

Page 39: ...963857132_I 38...

Page 40: ...963857132_I 39...

Page 41: ...963857132_I 40...

Page 42: ...963857132_I 41...

Page 43: ...any information storage and retrieval system without permission and writing from the publisher Tous droits de traduction reproduction et adaptation totale ou partielle de tout genre y compris les copi...

Page 44: ...pe Gmbh Heilswannenweg 50 31008 Elze Germany T 49 5068 462 400 F 49 5068 462 409 Germany MarelliMotori com sales DE MarelliMotori com Spain Representative Office 08195 Sant Cugat Barcelona Spain T 34...