51
Function setting
Press the key
Input desired
Parameter code
Press the key
Display shows the existing
parameter code. Input
new code as required.
Press the key
Continue to another function setting
or press to escape
Item
Function
Setting value
Default
Parameter
Description
AnL- 01
Data type
0
As display
0
1
Gross
2
Net
AnL- 02
Signal output
0
Current output
0
1
Voltage output
AnL- 03
Weight in Lo
0 ~ 999999
When the weight reaches the value of that
in AnL-03, the current / voltage output is
changed to that configured in AnL-05.
0
AnL- 04
Weight in Hi
0 ~ 999999
When the weight reaches the value of that
in AnL-04, the current / voltage output is
changed to that configured in AnL-06,07.
30000
AnL- 05
Current in Lo
0 ~ 65535
10940
≒
4mA
10940
AnL- 06
Current in Hi
0 ~ 65535
54560
≒
20mA
54560
AnL- 07
Voltage in Hi
0 ~ 65535
50100
≒
10V
50100
Increment flashing
digit
Decrement flashing
digit
Move flashing point
left.
Move flashing point
right
Store data in
memory
Exit
/
Escape