Function Configuration Menu
Item
Function
Setting value
Default
Parameter
Description
SQ- 10
Discharge start delay
time
0.0 ~ 25.5
(sec)
Delay time before Discharge signal is ON.
0.0
SQ- 11
Discharge stop delay
time
0.0 ~ 25.5
(sec)
Delay time before Discharge signal is OFF.
0.0
SQ- 12
Discharge time
0.0 ~ 25.5
(sec)
Won’t activate internal discharge control
function, if set to 0.
0
Discharge input signal
Weight reach zero band
SQ- 10
Discharge output signal
SQ- 11
SQ- 13 Restart delay time
0.0 ~ 25.5
(sec)
Delay time before Restart signal is ON.
1.0
SQ- 14
Batching counts
0 ~ 255
(times)
Number of batch runs
0
one batch only
0
SQ- 15
Set the zero band in to
final weighing value
0
No setting
0
1
Setting
SQ- 16
Hi, OK, Lo
0
Comparison anytime
0
1
To compare at batch finish
2
To compare at external input signal
3
To compare at batching finish and external input signal.
4
Comparison auto
SQ- 17
Auto accu. weight /
counts
0
Disabled
0
1
Enabled
SQ- 18
The parameter
source in weight
comparison
0
Key in directly from front keypad
0
1
Input directly from rear interface
SQ- 19
Weight comparison
delay time
0.0 ~ 25.5
(sec)
Comparison delay time for Hi, OK, Lo
0.5
SQ- 20
TARE auto.
0
Press keypad TARE to TARE
0
1
TARE auto
SQ- 21
Discharge auto
0
Input from external input or keypad
0
1
Discharge auto + manual