13
GEF Group Function Setting
Item
Function
Setting value
Default
Parameter
Description
GEF-01
Digital Filter I
0
5 Hz
4
1
4.17 Hz
2
2.5 Hz
3
2.08 Hz
4
1.25 Hz
5
1.04 Hz
6
0.63 Hz
7
0.52 Hz
8
0.31 Hz
9
0.26 Hz
GEF-02
Digital Filter II
0
Disabled
2
1
Less filter
Greater
2
3
4
5
GEF-03
Key
– Locked
000000
111111
0
Normal
(lock disable)
The bits and front
panel key
positions are
related to each
other.
000000
1
Close
(lock enable)
GEF-04
“FUNC” function setting
Parameter
Description
0
Display Net / Gross weight
1
Setpoint parameter setting
2
Tare reset
3
Manual serial, parallel print output.
4
Start load
5
Stop load
6
Start comparison
7
Unload command
8
Totalise weight and counts
command
9
Clear totalised weight and counts
10
Hold mode
11
Escape Hold mode(I/O DSP)
12
Convert to Gross / Net / totalised
weight / totalised Count
1
GEF-05
“F1” function setting
0