MDE-3883 TRIND Retrofit Kits C00011-005
• 10/00
Page 29
MPD-3 Series Installation
PRELIMINARY
FCC 11/30
Installing TRIND™ Faceplate Assembly.
Perform the following steps for each side of unit.
For installing TRIND slide-in faceplates on PMI bezels, do the following:
1
Remove new TRIND faceplate assembly from box.
2
Peel adhesive backing off round gasket N23881-01. Install gasket adhesive side first to
sheet metal shield on back of faceplate to form seal around hole for cables on faceplate
assembly.
3
Feed ends of faceplate cables (with P1/2 connectors) through 3/4" hole on bezel
door drilled in Step 3 of “Providing Cable Access into Main Cabinet” on page 26.
4
Follow these directions to install new TRIND faceplate:
• Feed top edge of faceplate in to groove on top of door.
• Gently push bottom of faceplate in until faceplate drops into bottom groove.
• Secure in place with keylock.
5
Refer to MDE-2620, Graphics Panel Application for instructions on installing
graphics.
For installing TRIND™ bolt-on (stud type) faceplates, do the following:
1
Remove new TRIND faceplate assembly from box.
2
Remove existing manager keypad from bezel door, and use putty knife to remove
keypad gasket and adhesive residue from door.
3
Replace the door gasket removed in step 2 with adhesive backed gasket Q11659-
01.
4
Replace existing keypad and keypad cable with T17549-G1 keypad assembly and
R18163-G1 keypad cable, but do not install keypad on bezel door.
Note:At user’s discretion, new keypad can be placed behind brand panel lighting or
in the well behind the printer door, on either side of printer, provided cable is
run and secured properly and safe access is maintained.
5
Remove yellow tape on back of bezel door covering round hole.
6
Peel adhesive backing off round gasket N23881-01. Install gasket adhesive side
first to seal around hole on back of bezel door.
7