Dispenser Set-Up
Page 34
MDE-3883 TRIND Retrofit Kits C00011-005
• 10/00
PRELIMINARY
FCC 11/30
Dispenser Set-Up
Addressing Dispenser
Each dispenser on the G-Site controller must be addressed differently; no two
dispensers may have the same address. Address is at discretion of the installer.
Follow these steps:
1
From A side of unit, locate dip switches on power supply board (PCB) T20314-G1 in card
cage.
2
Using switches 2, 3, 4 and 5 address each dispenser according to the following
table:
Note: Switch one in down position is standalone mode selected, used for service
only.
Setting Baud Rate
For major oil company (MOC) TRIND™ installations there is no requirement to
set or change baud rate.
Switch Numbers = Value
1 = Standalone Mode
2 = 1
3 = 2
4 = 4
5 = 8
1
2
3
4
5
Dip switch down
Dip switch up
T20606-G4