AUTOMATIC WATER SOFTENER CHRONOMETRIC 

Series GIX 

 

TECHNICAL FEATURES 

 
 
 
 

 

 

        

GIX5   GIX8   GIX12 

 

Width [mm]:

    

 

 230      250        285 

Depth [mm]:   

 

 380     480         425 

Height [mm]:  

 

 515      540        650 

Weight [Kg]:     

 

 11 

      12          15 

Cylinder capacity :  [l]

:

   

   5 

        8          12 

Liters of resin [l]: 

 

  3.5       5.5         

  

 

 

 

 

 

Nominal flow rate at 4 bar:..                         1500 l/h 
Room temperature:                     Min 4°C Max 35°C 
Feed water temperature              Min 6°C Max 25°C 
Pressure of feed water: ....0,2 ÷ 0,8 MPa (2 ÷ 8 bar) 
Power supply: ........INPUT: 230V 50/60 Hz standard 
                                            120V       60 Hz optional 
Absorbed power:                                                 4 W 

 

 
 

 

 

 

 

Summary of Contents for DVA GIX Series

Page 1: ...eight mm 515 540 650 Weight Kg 11 12 15 Cylinder capacity l 5 8 12 Liters of resin l 3 5 5 5 9 Nominal flow rate at 4 bar 1500 l h Room temperature Min 4 C Max 35 C Feed water temperature Min 6 C Max 25 C Pressure of feed water 0 2 0 8 MPa 2 8 bar Power supply INPUT 230V 50 60 Hz standard 120V 60 Hz optional Absorbed power 4 W ...

Page 2: ...eration cycles When operating it displays current time and day as well as the days on which rigeneration is scheduled During a regeneration cycle the displays shows time to completion as well as the stage it is in The information displpayed can be locked so as to avoid hazardous data modification INSTALLATION INSTRUCTIONS We suggest installing the equipment A NON RETURN VALVE B OUTLET TAP C BY PAS...

Page 3: ...all a pipe that keeps a few meters distance at least 3 between the outlet of the water softener and the inlet of the boiler Keep away from corrosive or acid products CONNECTION TO THE DRAIN SYSTEM A The drain pipe is not flattened or bent as water should flow without impedements THE OVERFILL PROTECTION PIPE B Insert flexible pipe in the quick joint then connect the pipe to a floor sink that must b...

Page 4: ... cycle Such device uses salt so as to carry out resin disinfection If salt is not present the device will not start Once the regeneration cycle is over an orange led light will turn on this means that salt shall be added in brine MAINTENANCE FOR THE INSTALLER For the equipment to work in optimal conditions we suggest performing the following operations periodically Clean the injector fig 6 B its f...

Page 5: ...er only consists in refilling the brine periodically with sodium chloride NaCl common salt If salt is lacking the water softener will not be able to soften the water AMOUNT OF SALT GIX5 GIX8 GIX12 Salt of rigeneration kg 0 6 1 1 5 Salt in the brine tank kg 10 20 25 LITRES OF SOFT WATER BASED ON WATER HARDNESS f d ppm CaCO3 20 11 200 30 16 300 40 22 400 50 28 500 60 33 600 Cyclic Capacity m 3 f GIX...

Reviews: