No. 7  Sets the mode the machine works in: 

  HEAT FILL (default 

– minimises 

temperature fluctuations), 

  CONT FILL (continuous fill 

– makes sure 

the tank is always full but temperature 
may vary), 

  COOL FILL (allows cooling but reduces 

tank size by using  ECO mode), 

  MANUAL (manual filling). 

  See further explanations pg 8 

HEAT 

FILL 

 

No. 8   Sets temperature units on screen. 

Celsius 

 

No.9  This sets max limit of the temperature that 
user can set in USER SETUP; max value is 
98.5 deg C  

Celsius 

 

No.10  Press the 

eco

 button to save all the 

values and reset the machine. 

 
 

 
DISPL AY INFORMATION DESCRIPTIONS:  

Status 

Description 

BOILER OFF 

Machine off. Display backlight off but temperature read-
out still working. 

FILLING ... 

Water level below low level probe. Machine is filling 
automatically. Status LED 

– 2 red blinks. 

FILL THE TANK 

Water level below low level probe. Machine has to be 
refilled manually (shown only in MANUAL mode).  
Status LED 

– 2 red blinks. 

WAIT ... 

Water is being heated. Dispense valve disabled. 

BOILER READY 

Water is up to the temperature and can be used. Note that 
this only means that the tank is heated and not that it is 
full. 
Status LED 

– green. 

DISPENSE 

Water is being dispensed. If machine is set to time 
dispenses 

– there will also be a progress bar drawn 

underneath. Dispense can always be cancelled by clicking 
the dispense button again. 

COOLING ... 

Machine was set by the user to a lower temperature than 
the current tank temperature and is trying to cool down by 
taking in more cold water. This process may take between 
20 seconds to a few minutes depending on tank size and 
temperature difference. Works only in COOL FILL mode. 

Summary of Contents for Ecoboiler UC10L 2.8kW

Page 1: ...e alphanumeric characters Water pressure 5 50 psi min max 35 345 kPa min max E337347 NSF ANSI 4 Marco Beverage Systems Limited 63d Heather Road Sandyford Industrial Estate Dublin 18 Marco Beverage Sys...

Page 2: ...epartment or similar function departments INSTALLATION DETAILS Electrical installation When installing the product always observe the local regulations and standards Products without an electrical plu...

Page 3: ...give a significant energy usage improvement over a standard water boiler All under counters incorporate a tank ECO mode function To enable the ECO Mode press the button located below the Ready indicat...

Page 4: ...ow the main screen Welcome screen with version number Main screen Top part of the display always shows live read out of the tank temperature 0 5 C accuracy Bottom part shows current machine status Ent...

Page 5: ...rvice Setup below Resolution 0 5 C 95 0 Sets dispense time Range 0 99 9 seconds Resolution 0 1 second For PUSH HOLD mode set to 0 default 00 0 Sets number of pauses during time dispense Range 0 20 If...

Page 6: ...ower This is a factory setting and should only be changed by trained personnel Range 0 20 0 seconds Resolution 0 1 second 3 0 2 8kW 6 0 5 6kW 9 0 8 4kW No 4 Sets the time at which machine waits for th...

Page 7: ...r level below low level probe Machine is filling automatically Status LED 2 red blinks FILL THE TANK Water level below low level probe Machine has to be refilled manually shown only in MANUAL mode Sta...

Page 8: ...COMM ERROR Display board lost communication with boiler PCB can not receive serial data about temperature and probes All actions cancelled Modes of Operations Service setup setting 5 Modes of OPERATIO...

Page 9: ...he boilers operating period for a given day switch the machine to ECO Mode Whilst maintaining water at 96o C the machine tank will slowly drop to half full where it will remain o At the end of the mac...

Page 10: ...e by hand paying particular attention to level probes White plastic with steel tab Be very careful not to damage any attachments Use ScaleKleen Marco part No 8000270 or similar Follow instructions car...

Page 11: ...a large enough container FONT INSTALLATION The font is connected to the machine by a silicone hose and a control wire The button on the font triggers the pump in either push and hold or push and relea...

Page 12: ...nt connection with ball valve Vent may be plumbed to a drain however there must be an air gap to prevent the possibility of a blocked drain flowing into the boiler Service Panel Controls 2 wire Electr...

Page 13: ...manually emptied Or Connected to a drain via drip tray outlet UC 4L 2 Wire Electrical Connection Font to Boiler Font connection with ball valve Service Panel Controls Vent may be plumbed to a drain ho...

Page 14: ...4 requirements when installing an NSF listed undercounter boiler with an NSF listed Uber Font The Vent pipe on the boiler MUST be connected to the Font Vent hose grey coloured hose Font connection Ven...

Page 15: ...when cleaning the front of the machine LIMESCALE In common with all water boiler manufacturers service calls resulting from lime scale are not covered by warranty Fitting a scale reducer is recommende...

Reviews: