EcoSmart Fea ture s  (ECOSM ART M ACHINES ONLY) : 

 

The EcoSmart Eco boile r has man y se ttable features wh ich give s the operator 

great fle xib il ity in choosin g ho w the  unit will ope rate. The follo win g e xpla ins how the 
va riou s features m ay be chan ged and their function .  
 
There are two  Men us in the EcoSmart Boile r   

One is to set the  USER SETUP  and  
One is to set the SERVICE SETUP  pa rameter. 

HOW TO SETUP  AN EcoSM ART:  

 

Smart Boiler  (software Revision 1.10) 

After few seconds the display will show the main screen: 

 

      

 

Welcome screen with version number     

Main screen 

 

  Top part of the display always shows live read-out of the tank temperature (0.5°C accuracy). 

  Bottom part shows current machine status.  

 

Entering Setup Mode 

  To enter setup mode press 

power

 and 

eco

 buttons on the front panel at the same time. 

 

The display will show “USER SETUP” message: 

 

  Release the buttons now to enter the user setup mode. 

 

To enter advanced settings keep the buttons pressed until the display shows “SERVICE 
SETUP” message and release them. 

 

  In both setup modes use front panel buttons to navigate the settings: 

o

 

power

 button to scroll through the functions, 

o

 

eco

 button to increase set value (press and hold for auto-repeat). 

 
 
 
 
 
 

Summary of Contents for Ecoboiler UC10L 2.8kW

Page 1: ...e alphanumeric characters Water pressure 5 50 psi min max 35 345 kPa min max E337347 NSF ANSI 4 Marco Beverage Systems Limited 63d Heather Road Sandyford Industrial Estate Dublin 18 Marco Beverage Sys...

Page 2: ...epartment or similar function departments INSTALLATION DETAILS Electrical installation When installing the product always observe the local regulations and standards Products without an electrical plu...

Page 3: ...give a significant energy usage improvement over a standard water boiler All under counters incorporate a tank ECO mode function To enable the ECO Mode press the button located below the Ready indicat...

Page 4: ...ow the main screen Welcome screen with version number Main screen Top part of the display always shows live read out of the tank temperature 0 5 C accuracy Bottom part shows current machine status Ent...

Page 5: ...rvice Setup below Resolution 0 5 C 95 0 Sets dispense time Range 0 99 9 seconds Resolution 0 1 second For PUSH HOLD mode set to 0 default 00 0 Sets number of pauses during time dispense Range 0 20 If...

Page 6: ...ower This is a factory setting and should only be changed by trained personnel Range 0 20 0 seconds Resolution 0 1 second 3 0 2 8kW 6 0 5 6kW 9 0 8 4kW No 4 Sets the time at which machine waits for th...

Page 7: ...r level below low level probe Machine is filling automatically Status LED 2 red blinks FILL THE TANK Water level below low level probe Machine has to be refilled manually shown only in MANUAL mode Sta...

Page 8: ...COMM ERROR Display board lost communication with boiler PCB can not receive serial data about temperature and probes All actions cancelled Modes of Operations Service setup setting 5 Modes of OPERATIO...

Page 9: ...he boilers operating period for a given day switch the machine to ECO Mode Whilst maintaining water at 96o C the machine tank will slowly drop to half full where it will remain o At the end of the mac...

Page 10: ...e by hand paying particular attention to level probes White plastic with steel tab Be very careful not to damage any attachments Use ScaleKleen Marco part No 8000270 or similar Follow instructions car...

Page 11: ...a large enough container FONT INSTALLATION The font is connected to the machine by a silicone hose and a control wire The button on the font triggers the pump in either push and hold or push and relea...

Page 12: ...nt connection with ball valve Vent may be plumbed to a drain however there must be an air gap to prevent the possibility of a blocked drain flowing into the boiler Service Panel Controls 2 wire Electr...

Page 13: ...manually emptied Or Connected to a drain via drip tray outlet UC 4L 2 Wire Electrical Connection Font to Boiler Font connection with ball valve Service Panel Controls Vent may be plumbed to a drain ho...

Page 14: ...4 requirements when installing an NSF listed undercounter boiler with an NSF listed Uber Font The Vent pipe on the boiler MUST be connected to the Font Vent hose grey coloured hose Font connection Ven...

Page 15: ...when cleaning the front of the machine LIMESCALE In common with all water boiler manufacturers service calls resulting from lime scale are not covered by warranty Fitting a scale reducer is recommende...

Reviews: