background image

1900052 

                                                    REV.6 

 

 

 

Page 5 

 
 
 
 
 

USER SET UP OPTIONS:  

User Setup 

Screen view 

Description 

Default 

value 

 

Sets new tank temperature. 

NOTE:

 Temperature should never be set for 

more than 97°C because it may cause steam 
to be generated during the low pressure days. 
Range: 60 

– 98.5 °C 

Range can be limited in Service Settings, see 
Service Setup below.

 

Resolution: 0.5 °C 

95.0 

 

Sets dispense time. 
Range: 0 

– 99.9 seconds 

Resolution: 0.1 second 
For PUSH & HOLD mode set to 0 (default). 

00.0 

 

Sets number of pauses during time dispense. 
Range: 0 

– 20 

If machine set as PUSH & HOLD then number 
of pauses has no impact on dispense. 

00 

 

Sets pause time (same for each of the pauses). 
Range: 0 

– 20.0 seconds 

Resolution: 0.1 second 
If machine set as PUSH & HOLD then time of 
pause has no impact on dispense. 

00.0 

 

Press the 

eco

 button to save all the values and 

reset the machine. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for Ecoboiler UC10L 2.8kW

Page 1: ...e alphanumeric characters Water pressure 5 50 psi min max 35 345 kPa min max E337347 NSF ANSI 4 Marco Beverage Systems Limited 63d Heather Road Sandyford Industrial Estate Dublin 18 Marco Beverage Sys...

Page 2: ...epartment or similar function departments INSTALLATION DETAILS Electrical installation When installing the product always observe the local regulations and standards Products without an electrical plu...

Page 3: ...give a significant energy usage improvement over a standard water boiler All under counters incorporate a tank ECO mode function To enable the ECO Mode press the button located below the Ready indicat...

Page 4: ...ow the main screen Welcome screen with version number Main screen Top part of the display always shows live read out of the tank temperature 0 5 C accuracy Bottom part shows current machine status Ent...

Page 5: ...rvice Setup below Resolution 0 5 C 95 0 Sets dispense time Range 0 99 9 seconds Resolution 0 1 second For PUSH HOLD mode set to 0 default 00 0 Sets number of pauses during time dispense Range 0 20 If...

Page 6: ...ower This is a factory setting and should only be changed by trained personnel Range 0 20 0 seconds Resolution 0 1 second 3 0 2 8kW 6 0 5 6kW 9 0 8 4kW No 4 Sets the time at which machine waits for th...

Page 7: ...r level below low level probe Machine is filling automatically Status LED 2 red blinks FILL THE TANK Water level below low level probe Machine has to be refilled manually shown only in MANUAL mode Sta...

Page 8: ...COMM ERROR Display board lost communication with boiler PCB can not receive serial data about temperature and probes All actions cancelled Modes of Operations Service setup setting 5 Modes of OPERATIO...

Page 9: ...he boilers operating period for a given day switch the machine to ECO Mode Whilst maintaining water at 96o C the machine tank will slowly drop to half full where it will remain o At the end of the mac...

Page 10: ...e by hand paying particular attention to level probes White plastic with steel tab Be very careful not to damage any attachments Use ScaleKleen Marco part No 8000270 or similar Follow instructions car...

Page 11: ...a large enough container FONT INSTALLATION The font is connected to the machine by a silicone hose and a control wire The button on the font triggers the pump in either push and hold or push and relea...

Page 12: ...nt connection with ball valve Vent may be plumbed to a drain however there must be an air gap to prevent the possibility of a blocked drain flowing into the boiler Service Panel Controls 2 wire Electr...

Page 13: ...manually emptied Or Connected to a drain via drip tray outlet UC 4L 2 Wire Electrical Connection Font to Boiler Font connection with ball valve Service Panel Controls Vent may be plumbed to a drain ho...

Page 14: ...4 requirements when installing an NSF listed undercounter boiler with an NSF listed Uber Font The Vent pipe on the boiler MUST be connected to the Font Vent hose grey coloured hose Font connection Ven...

Page 15: ...when cleaning the front of the machine LIMESCALE In common with all water boiler manufacturers service calls resulting from lime scale are not covered by warranty Fitting a scale reducer is recommende...

Reviews: