SERVICE SETUP OPTIONS:
Screen view
Description
Default
value
No. 1 Sets and shows remaining weeks before
de-
scaling is needed (“DESCALE TANK”
message on the screen).
Setting it to OFF will disable the function.
Range: 1
– 60 weeks
OFF
No. 2 Sets and shows remaining litres of water
before filter change is needed (“CHANGE
FILTER” message on the screen).
Setting it to OFF will disable the function.
Range: 100
– 9900 litres
OFF
No. 3 Sets the time for which the inlet opens
every time the machine needs water. It
minimises temperature fluctuations. The value
should be picked to allow 0.5 - 1°C cooling
after water intake and depends on the tank size
and element power. This is a factory setting and
should only be changed by trained personnel.
Range: 0
– 20.0 seconds
Resolution: 0.1 second
3.0
(2.8kW)
6.0
(5.6kW)
9.0
(8.4kW)
No. 4 Sets the time at which machine waits for
the water too cool down after water intake.
Measured from the beginning of the water
intake. The value depends on tank size and
element power. This is a factory setting and
should only be changed by trained personnel.
Range: 0
– 60.0 seconds
Resolution: 0.5 second
12.0
No. 5 “SERV PIN” limits access to SERVICE
SETUP, setting it to 0000 disables the pin
(default)
OFF
No. 6 PIN entry screen - once PIN is set and
user wants to access SERVICE SETUP this
screen will pop up; use top button to move
through positions and bottom to scroll through
the values (0 to 9 and again 0); if PIN is
accepted you will gain access to the SERVICE
SETUP, if PIN is rejected machine will reset
itself.