ES2060 Quantification Dispenser Manual 

1.  Package contains the following items

 

z

 ES2060 

Quantification Dispenser 

z

 Power 

Cord 

z

 

Air Pressure Connector 

z

 Barrel 

Adapter 

Set 

z

 Startup 

Kit 

z

 

Foot Pedal or Finger Switch 

 

2. Hardware Setup

 

a. 

Please connect the Air Pressure Connector on the back of the system to the nearby air compressor line. 

b. 

Connect the Foot Pedal on the back of the system or Finger Switch on the front of the system. 

c. 

Fill the dispensing barrel with adhesive up to 2/3 full and adapt with barrel adapter. Connect the adapter to the 

front of the system. 

d. 

If you are using Finger Switch, please stick the switch on the dispensing barrel. 

e. 

Connect the Power Cord on the back of the system and switch the power on. Please make sure all the display 

and light indicator are working properly. (110V-240V full voltage) 

f. 

Install the dispensing barrel with appropriate needle and adjust with appropriate air pressure and vacuum. 

(Please refer to Table 1) 

 

 

 

 

Summary of Contents for ES2060

Page 1: ...ressor line b Connect the Foot Pedal on the back of the system or Finger Switch on the front of the system c Fill the dispensing barrel with adhesive up to 2 3 full and adapt with barrel adapter Connect the adapter to the front of the system d If you are using Finger Switch please stick the switch on the dispensing barrel e Connect the Power Cord on the back of the system and switch the power on P...

Page 2: ...se dispensing you will need to use low pressure dispenser 0 30 psi 3 Control Setting 1 Pressure Indicator Display the currently air pressure in the system 2 Pressure Regulator Adjust the air pressure in the system increase with clockwise and decrease with counter clockwise 3 Barrel Adapter Port Connect with barrel adapter press down and rotate to adapt 4 Vacuum Knob Adjust the suck back pressure i...

Page 3: ...ly If the adhesive cannot flow out the barrel please adjust the pressure or replace the needle and repeat step a again d Place the barrel 45 degree to the process object and fit the needle on top of the dispensing point e Manual dispensing turn off the timer switch and step on the foot pedal to activate the dispensing remove to stop the dispensing It is suitable for long straight line and irregula...

Page 4: ...tional or place the barrel on the barrel stand to prevent solidification 7 Troubleshooting Problem Possible Cause Correction Indicator or display does not light no power input PCB main board damage check power cord connection turn on power replace new PCB main board Cannot dispense foot pedal not plugged in properly defective foot pedal foot pedal port broken or loosen defective Solenoid Valve che...

Page 5: ...ive product or subassembly and components under warranty will be repaired or replaced at Ever Sharp option free of charge Customer with defective product under warranty must contact the nearest Ever Sharp office or distributor to secure a return authorization prior to shipping the product to the assigned Ever Sharp authorized service center For nearest Ever Sharp office or distributor contact info...