Administrator Se ngs: modify the administrator
password, the default password is "111111".
output se ng:
The output se ng includes a hidden An -Clip limiter:
Max input Level is +20dBu and Max output level is
+18dBu, this means that when input is going over
+18dBu, if no Limit process on output, the output will
be clipped up to +2dB in excess.
The An -Clip Limiter is Limi ng up to +2dBu the
output when input is exceeding +18dBu, e nd all
processes are in Flat. It is turned on by default.
32
MIR-A
MIR-A Speaker Management
Software specification
Plug-in func on: Extra processes can be
added in plug in shape on Input path, in
addi on to the fixed processes of the MIR
controller. Plug-ins will be made available
in me. The first available Plug ins are
including.
1
.Single channel 96kHz sampling rate 1536 taps FIR
filter.
2
.Dual channel 96kHz sampling rate 760 taps FIR
filter.
3
.60-band RTA spectrum analysis and advanced
signal generator.
Plug-in 1 is applied to
channel A by default.
6
6
Plug-in
C h a n n e l s w i t h o u t
plugins are empty here