62
Step 3
Disconnect the harvest float switch wire from
the control board and place a jumper on the control
board harvest float switch terminals. Bypass the freeze
time lock-in feature by pressing the power button to
cycle the ice machine off/on. Wait until water flows over
the evaporator, then refer to chart.
Result
Correction
10 seconds into the freeze cycle
the ice machine cycles from freeze
to harvest and the control board
harvest light energizes.
The ice thickness float
switch wire is causing the
malfunction.
The harvest light comes on, but the
ice machine remains in the freeze
cycle.
The ice machine is in a 6
minute freeze lock - Cycle
on/off and retest.
The harvest light stays off and the
ice machine remains in freeze.
Replace the control
board.
Summary of Contents for STH042 4/16
Page 2: ......
Page 14: ...14 Part Number STH042 4 16 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 42: ...42 Part Number STH042 4 16 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 56: ...56 Part Number STH042 4 16 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 98: ...98 Part Number STH042 4 16 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 126: ...126 Part Number STH042 4 16 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 136: ...136 Part Number STH042 4 16 U140 U190 U240 WIRING DIAGRAM WITHOUT J4 THERMISTOR TERMINAL ...
Page 137: ...Part Number STH042 4 16 137 U310 WIRING DIAGRAM WITHOUT J4 THERMISTOR TERMINAL ...
Page 138: ...138 Part Number STH042 4 16 U140 U190 U240 WIRING DIAGRAM WITH J4 THERMISTOR TERMINAL ...
Page 139: ...Part Number STH042 4 16 139 U310 WIRING DIAGRAM WITH J4 THERMISTOR TERMINAL ...
Page 144: ...144 Part Number STH042 4 16 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 145: ......