Preventative Maintenance Cleaning
This cleaning procedure can be performed between the
bi-annual cleaning and sanitizing cycles. This procedure
does not require removing the ice from the bin.
Step 1
Press the On/Off button after ice falls from the
evaporator at the end of a Harvest cycle. Or, press the On/
Off button and allow the ice to melt off the evaporator.
,
Caution
Never use anything to force ice from the evaporator.
Damage may result.
n
Warning
Wear rubber gloves and safety goggles (and/or
face shield) when handling Ice Machine Cleaner or
Sanitizer.
Step 2
To start a cleaning cycle, press the Clean
button. Water will flow through the water dump valve
and down the drain. Wait until the water trough refills,
then add the proper amount of ice machine cleaner to
the water trough.
Model
Amount of Cleaner
U0140
2 ounce (60 ml)
U0190
5 ounces (150 ml)
U0240
5 ounces (150 ml)
U0310
5 ounces (150 ml)
Wait until the clean cycle is complete (approximately 22
minutes) then press the On/Off button.
Summary of Contents for STH042 4/16
Page 2: ......
Page 14: ...14 Part Number STH042 4 16 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 42: ...42 Part Number STH042 4 16 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 56: ...56 Part Number STH042 4 16 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 98: ...98 Part Number STH042 4 16 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 126: ...126 Part Number STH042 4 16 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 136: ...136 Part Number STH042 4 16 U140 U190 U240 WIRING DIAGRAM WITHOUT J4 THERMISTOR TERMINAL ...
Page 137: ...Part Number STH042 4 16 137 U310 WIRING DIAGRAM WITHOUT J4 THERMISTOR TERMINAL ...
Page 138: ...138 Part Number STH042 4 16 U140 U190 U240 WIRING DIAGRAM WITH J4 THERMISTOR TERMINAL ...
Page 139: ...Part Number STH042 4 16 139 U310 WIRING DIAGRAM WITH J4 THERMISTOR TERMINAL ...
Page 144: ...144 Part Number STH042 4 16 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 145: ......