23
Water-cooled Ice Machine
Ice Machine
Voltage
Phase Cycle
Max. Fuse/
Circuit
Breaker
Total Amps
U140
115/1/60
15
5.0
208-230/1/60
15
2.5
230/1/50
15
2.5
U240
115/1/60
15
7.0
208-230/1/60
15
4.0
230/1/50
15
4.0
U310
115/1/60
15
10.0
208-230/1/60
15
4.5
230/1/50
15
4.5
n
Warning
All wiring must conform to local, state and national
codes.
n
Warning
The ice machine must be grounded in accordance
with national and local electrical code.