Part Number 80-1505-3 6/11
269
SD3072C/CVD3085 SERIES REMOTE AIR COOLED
NOTE: These characteristics may vary depending on
operating conditions.
CYCLE TIMES
24-HOUR ICE PRODUCTION
OPERATING PRESSURES
NOTE: CVD3085 Models - Verify the direction of rotation correct is
correct on the 3ph scroll compressor. The ice machine will have high
suction pressure, low discharge pressure and will be noticeably loud.
Reverse any two incoming power leads to reverse rotation.
Freeze Time + Harvest Time = Cycle Time
Air Temp.
Entering
Condenser
°F/°C
Freeze Time
Harvest
Time
Water Temperature °F/°C
50/10
70/21
90/32
-20 to 70/
-29 to 21
10.9-12.4
11.8-13.4
12.6-14.3
0.75-2.5
90/32
12.3-14.0
13.4-15.4
14.5-16.5
100/38
13.2-15.0
14.5-16.5
15.7-17.8
110/43
14.5-16.5
16.1-18.3
17.6-19.9
1
Times in minutes.
Air Temp.
Entering
Condenser
°F/°C
Water Temperature °F/°C
50/10
70/21
90/32
-20 to 70/
-29 to 21
2850
2650
2500
90/32
2550
2350
2200
100/38
2400
2200
2050
110/43
2200
2000
1850
1
Based on average ice weight of one Harvest cycle 24.5-27.5 lb.
(6.38-7.13 lb. per evaporator).
Air Temp.
Entering
Condenser
°F/°C
Freeze Cycle
Harvest Cycle
Discharge
Pressure
psig
Suction
Pressure
psig
Discharge
Pressure
psig
Suction
Pressure
psig
-20 to 70/
-29 to 21
250-220
48-30
135-150
70-85
80/27
300-240
50-30
145-170
70-90
90/32
320-280
55-32
165-190
80-100
100/38
350-310
60-33
180-200
90-110
110/43
400-350
65-35
180-210
100-115
During low ambient conditions, it is normal for the head pressure
control valve to hunt (fluctuate up and down) on CVD condensing
units. Hunting varies by model and ambient temperature, but
generally settles out within the first 6 minutes of the freeze cycle
Summary of Contents for SD0672C
Page 2: ......
Page 65: ...Part Number 80 1505 3 6 11 65 This Page Intentionally Left Blank ...
Page 66: ...66 Part Number 80 1505 3 6 11 This Page Intentionally Left Blank ...
Page 79: ...Part Number 80 1505 3 6 11 79 A B C D ...
Page 81: ...Part Number 80 1505 3 6 11 81 A B C D E I ...
Page 90: ...90 Part Number 80 1505 3 6 11 A B C D E F G ...
Page 94: ...94 Part Number 80 1505 3 6 11 A B C E F D G H ...
Page 97: ...Part Number 80 1505 3 6 11 97 A B C D F G E ...
Page 100: ...100 Part Number 80 1505 3 6 11 A B C D E F G H ...
Page 174: ...174 Part Number 80 1505 3 6 11 This Page Intentionally Left Blank ...
Page 198: ...198 Part Number 80 1505 3 6 11 This Page Intentionally Left Blank ...
Page 229: ...Part Number 80 1505 3 6 11 229 SV1406 USING PINCH OFF TOOL ...
Page 232: ...232 Part Number 80 1505 3 6 11 ...
Page 238: ...238 Part Number 80 1505 3 6 11 This Page Intentionally Left Blank ...
Page 276: ...276 Part Number 80 1505 3 6 11 S3070C 230V 50HZ 1PH ...
Page 283: ...Part Number 80 1505 3 6 11 283 CVD3085 380V 50HZ 3PH ...
Page 296: ...296 Part Number 80 1505 3 6 11 This Page Intentionally Left Blank ...
Page 297: ......