Part Number 80-1505-3 6/11
181
IB Model Ice Machines
Before Serial Number 050400000
FUNCTION
The switch is used to place the ice machine in ICE,
OFF or CLEAN mode of operation.
SPECIFICATIONS
Double-pole, double-throw switch. The switch is
connected into a varying low D.C. voltage circuit.
CHECK PROCEDURE
NOTE: Because of a wide variation in D.C. voltage, it
is not recommended that a voltmeter be used to check
toggle switch operation.
1. Inspect the toggle switch for correct wiring.
2. Isolate the toggle switch by disconnecting all
wires from the switch, or by disconnecting the
Molex connector and removing wire #69 from the
toggle switch.
3. Check across the toggle switch terminals using a
calibrated ohmmeter. Note where the wire
numbers are connected to the switch terminals, or
refer to the wiring diagram to take proper
readings.
4. Replace the toggle switch if ohm readings do not
match all three switch settings.
Switch
Setting
Terminals
Ohm Reading
ICE
66-62
Open
67-68
Closed
67-69
Open
CLEAN
66-62
Closed
67-68
Open
67-69
Closed
OFF
66-62
Open
67-68
Open
67-69
Open
Summary of Contents for SD0672C
Page 2: ......
Page 65: ...Part Number 80 1505 3 6 11 65 This Page Intentionally Left Blank ...
Page 66: ...66 Part Number 80 1505 3 6 11 This Page Intentionally Left Blank ...
Page 79: ...Part Number 80 1505 3 6 11 79 A B C D ...
Page 81: ...Part Number 80 1505 3 6 11 81 A B C D E I ...
Page 90: ...90 Part Number 80 1505 3 6 11 A B C D E F G ...
Page 94: ...94 Part Number 80 1505 3 6 11 A B C E F D G H ...
Page 97: ...Part Number 80 1505 3 6 11 97 A B C D F G E ...
Page 100: ...100 Part Number 80 1505 3 6 11 A B C D E F G H ...
Page 174: ...174 Part Number 80 1505 3 6 11 This Page Intentionally Left Blank ...
Page 198: ...198 Part Number 80 1505 3 6 11 This Page Intentionally Left Blank ...
Page 229: ...Part Number 80 1505 3 6 11 229 SV1406 USING PINCH OFF TOOL ...
Page 232: ...232 Part Number 80 1505 3 6 11 ...
Page 238: ...238 Part Number 80 1505 3 6 11 This Page Intentionally Left Blank ...
Page 276: ...276 Part Number 80 1505 3 6 11 S3070C 230V 50HZ 1PH ...
Page 283: ...Part Number 80 1505 3 6 11 283 CVD3085 380V 50HZ 3PH ...
Page 296: ...296 Part Number 80 1505 3 6 11 This Page Intentionally Left Blank ...
Page 297: ......