256
Part Number 80-1505-3 6/11
IB1022DC/CVD1185 SERIES REMOTE AIR
COOLED MACHINES AFTER SERIAL NUMBER
110697294
NOTE: These characteristics may vary depending on
operating conditions.
CYCLE TIMES
24-HOUR ICE PRODUCTION
OPERATING PRESSURES
Freeze Time + Harvest Time = Cycle Time
Air Temp.
Entering
Condenser
°F/°C
Freeze Time
Harvest
Time
Water Temperature °F/°C
50/10
70/21
90/32
-20 to 70/
-29 to 21
9.5-11.0
10.4-12.0
11.3-13.0
.75-2.5
90/32
10.3-11.9
10.6-12.3
12.2-14.0
100/38
10.8-12.4
11.7-13.4
12.7-14.6
110/43
11.2-12.9
12.2-14.0
13.3-15.3
1
Times in minutes.
Air Temp.
Entering
Condenser
°F/°C
Water Temperature °F/°C
50/10
70/21
90/32
-20 to 70/
-29 to 21
980
910
845
90/32
915
890
790
100/38
880
820
760
110/43
850
790
730
1
Based on average ice slab weight of 7.5-8.5 lb.
Air Temp.
Entering
Condenser
°F/°C
Freeze Cycle
Harvest Cycle
Discharge
Pressure
psig
Suction
Pressure
psig
Discharge
Pressure
psig
Suction
Pressure
psig
-20 to 50/
-29 to 10
200-250
40-25
140-170
65-75
70/21
220-270
40-25
150-185
65-85
80/27
225-275
50-26
160-190
70-90
90/32
235-275
60-27
175-195
75-95
100/38
260-325
65-30
190-220
80-100
110/43
300-360
70-33
200-230
90-105
During low ambient conditions, it is normal for the head pressure
control valve to hunt (fluctuate up and down) on CVD condensing
units. Hunting varies by model and ambient temperature, but
generally settles out within the first 6 minutes of the freeze cycle.
Summary of Contents for SD0672C
Page 2: ......
Page 65: ...Part Number 80 1505 3 6 11 65 This Page Intentionally Left Blank ...
Page 66: ...66 Part Number 80 1505 3 6 11 This Page Intentionally Left Blank ...
Page 79: ...Part Number 80 1505 3 6 11 79 A B C D ...
Page 81: ...Part Number 80 1505 3 6 11 81 A B C D E I ...
Page 90: ...90 Part Number 80 1505 3 6 11 A B C D E F G ...
Page 94: ...94 Part Number 80 1505 3 6 11 A B C E F D G H ...
Page 97: ...Part Number 80 1505 3 6 11 97 A B C D F G E ...
Page 100: ...100 Part Number 80 1505 3 6 11 A B C D E F G H ...
Page 174: ...174 Part Number 80 1505 3 6 11 This Page Intentionally Left Blank ...
Page 198: ...198 Part Number 80 1505 3 6 11 This Page Intentionally Left Blank ...
Page 229: ...Part Number 80 1505 3 6 11 229 SV1406 USING PINCH OFF TOOL ...
Page 232: ...232 Part Number 80 1505 3 6 11 ...
Page 238: ...238 Part Number 80 1505 3 6 11 This Page Intentionally Left Blank ...
Page 276: ...276 Part Number 80 1505 3 6 11 S3070C 230V 50HZ 1PH ...
Page 283: ...Part Number 80 1505 3 6 11 283 CVD3085 380V 50HZ 3PH ...
Page 296: ...296 Part Number 80 1505 3 6 11 This Page Intentionally Left Blank ...
Page 297: ......