Part Number 80-1505-3 6/11
135
COMPRESSOR ELECTRICAL DIAGNOSTICS
The compressor does not start or will trip repeatedly
on overload.
Check Resistance (Ohm) Values
NOTE: Compressor windings can have very low ohm
values. Use a properly calibrated meter.
Perform the resistance test after the compressor
cools. The compressor dome should be cool enough
to touch (below 120°F/49°C) to assure that the
overload is closed and the resistance readings will be
accurate.
Single Phase Compressors
1. Disconnect power then remove the wires from the
compressor terminals.
2. The resistance values between C and S and
between C and R, when added together, should
equal the resistance value between S and R.
3. If the overload is open, there will be a resistance
reading between S and R, and open readings
between C and S and between C and R. Allow the
compressor to cool, then check the readings
again.
Three Phase Compressors
1. Disconnect power and remove the wires from the
compressor terminals.
2. The resistance values between L1 and L2,
between L2 and L3, and between L3 and L1
should all be equal.
3. If the overload is open, there will be open
readings between L1 and L2, between L2 and L3,
and between L3 and L1. Allow the compressor to
cool, then check the readings again.
Summary of Contents for SD0672C
Page 2: ......
Page 65: ...Part Number 80 1505 3 6 11 65 This Page Intentionally Left Blank ...
Page 66: ...66 Part Number 80 1505 3 6 11 This Page Intentionally Left Blank ...
Page 79: ...Part Number 80 1505 3 6 11 79 A B C D ...
Page 81: ...Part Number 80 1505 3 6 11 81 A B C D E I ...
Page 90: ...90 Part Number 80 1505 3 6 11 A B C D E F G ...
Page 94: ...94 Part Number 80 1505 3 6 11 A B C E F D G H ...
Page 97: ...Part Number 80 1505 3 6 11 97 A B C D F G E ...
Page 100: ...100 Part Number 80 1505 3 6 11 A B C D E F G H ...
Page 174: ...174 Part Number 80 1505 3 6 11 This Page Intentionally Left Blank ...
Page 198: ...198 Part Number 80 1505 3 6 11 This Page Intentionally Left Blank ...
Page 229: ...Part Number 80 1505 3 6 11 229 SV1406 USING PINCH OFF TOOL ...
Page 232: ...232 Part Number 80 1505 3 6 11 ...
Page 238: ...238 Part Number 80 1505 3 6 11 This Page Intentionally Left Blank ...
Page 276: ...276 Part Number 80 1505 3 6 11 S3070C 230V 50HZ 1PH ...
Page 283: ...Part Number 80 1505 3 6 11 283 CVD3085 380V 50HZ 3PH ...
Page 296: ...296 Part Number 80 1505 3 6 11 This Page Intentionally Left Blank ...
Page 297: ......