Part Number 80-1505-3 6/11
263
SD1872C/CVD1885 SERIES REMOTE AIR COOLED
NOTE: These characteristics may vary depending on
operating conditions.
CYCLE TIMES
24-HOUR ICE PRODUCTION
OPERATING PRESSURES
Freeze Time + Harvest Time = Cycle Time
Air Temp.
Entering
Condenser
°F/°C
Freeze Time
Harvest
Time
Water Temperature °F/°C
50/10
70/21
90/32
-20 to 70/
-29 to 21
11.1-13.1
12.0-13.1
13.1-14.3
.75-2.5
90/32
12.8-13.9
13.4-14.6
15.0-16.4
100/38
13.8-15.0
14.9-16.2
16.2-17.6
110/43
14.9-16.2
16.2-17.6
17.6-19.1
1
Times in minutes.
Air Temp.
Entering
Condenser
°F/°C
Water Temperature °F/°C
50/10
70/21
90/32
-20 to 70/
-29 to 21
1770
1650
1530
90/32
1565
1500
1350
100/38
1460
1360
1260
110/43
1360
1260
1170
1
Based on average ice weight of one Harvest cycle 15.5-16.75 lb.
(7.75-8.38 lb. per evaporator).
Air Temp.
Entering
Condenser
°F/°C
Freeze Cycle
Harvest Cycle
Discharge
Pressure
psig
Suction
Pressure
psig
Discharge
Pressure
psig
Suction
Pressure
psig
-20 to 70/
-29 to 21
215-250
60-30
140-155
65-90
80/27
215-260
60-33
140-155
65-90
90/32
240-280
60-34
145-165
65-95
100/38
250-295
60-35
150-170
65-95
110/43
290-365
60-36
160-190
75-100
120/49
300-380
60-37
170-200
80-110
During low ambient conditions, it is normal for the head pressure
control valve to hunt (fluctuate up and down) on CVD condensing
units. Hunting varies by model and ambient temperature, but
generally settles out within the first 6 minutes of the freeze cycle
Summary of Contents for SD0672C
Page 2: ......
Page 65: ...Part Number 80 1505 3 6 11 65 This Page Intentionally Left Blank ...
Page 66: ...66 Part Number 80 1505 3 6 11 This Page Intentionally Left Blank ...
Page 79: ...Part Number 80 1505 3 6 11 79 A B C D ...
Page 81: ...Part Number 80 1505 3 6 11 81 A B C D E I ...
Page 90: ...90 Part Number 80 1505 3 6 11 A B C D E F G ...
Page 94: ...94 Part Number 80 1505 3 6 11 A B C E F D G H ...
Page 97: ...Part Number 80 1505 3 6 11 97 A B C D F G E ...
Page 100: ...100 Part Number 80 1505 3 6 11 A B C D E F G H ...
Page 174: ...174 Part Number 80 1505 3 6 11 This Page Intentionally Left Blank ...
Page 198: ...198 Part Number 80 1505 3 6 11 This Page Intentionally Left Blank ...
Page 229: ...Part Number 80 1505 3 6 11 229 SV1406 USING PINCH OFF TOOL ...
Page 232: ...232 Part Number 80 1505 3 6 11 ...
Page 238: ...238 Part Number 80 1505 3 6 11 This Page Intentionally Left Blank ...
Page 276: ...276 Part Number 80 1505 3 6 11 S3070C 230V 50HZ 1PH ...
Page 283: ...Part Number 80 1505 3 6 11 283 CVD3085 380V 50HZ 3PH ...
Page 296: ...296 Part Number 80 1505 3 6 11 This Page Intentionally Left Blank ...
Page 297: ......