Part Number 80-1479-3 7/10
61
Harvest Sequence
5. Water Purge
The air compressor (when used) and the harvest
valve(s) open at the beginning of the water purge to
divert hot refrigerant gas into the evaporator.
The water pump continues to run, and the water dump
valve energizes to purge the water in the water trough.
Single evaporator models energize the water fill valve
for the last 15 seconds of the water purge cycle.
Energized Control Board Lights-
Single Evaporators = Left Bin (green), Harvest (red)
Quad Evaporators = All Curtain Switches (green),
Liquid Solenoid (red), Dump Valve (red), Water Pump
(red), Harvest (red), All Harvest Valves (red)