238
Part Number 80-1479-3 7/10
SY1204A
Half Dice Cube, Self-Contained Air-cooled After Serial
Number 110697023
Characteristics may vary depending on operating conditions.
CYCLE TIMES
Freeze Time + Harvest Time = Total Cycle Time
24 HOUR ICE PRODUCTION
OPERATING PRESSURES
Air Temp.
Entering
Condenser
°F/°C
Freeze Time
Harvest
Time
1
1 Times in minutes
Water Temperature °F/°C
50/10
70/21
90/32
70/21
7.5-8.4
8.2-9.2
9.1-10.2
0.75-2.0
80/27
8.2-9.2
9.0-10.0
10.0-11.1
90/32
9.0-10.1
9.9-11.1
11.0-12.2
100/38
10.1-11.2
11.0-12.2
12.1-13.4
110/43
11.3-12.6
12.3-13.6
13.5-15.0
Air Temp. Entering
Condenser
°F/°C
Water Temperature °F/°C
12
1 Based on average ice slab weight of 5.75 -6.5 lb
2 230/50/1 is approximately 12% lower than 230/60/1
50/10
70/21
90/32
70/21
1205
1110
1015
80/27
1115
1030
940
90/32
1025
945
865
100/38
935
865
795
110/43
845
785
720
Air Temp.
Entering
Condenser
°F/°C
Freeze Cycle
Harvest Cycle
Discharge
Pressure
PSIG
Suction
Pressure
PSIG
Discharge
Pressure
PSIG
Suction
Pressure
PSIG
1
1 Suction pressure drops gradually throughout the freeze cycle
50/10
195-255
40-23
135-155
65-85
70/21
220-280
50-24
140-180
70-90
80/27
240-300
50-24
155-180
75-95
90/32
265-340
55-25
175-195
85-100
100/38
310-390
60-28
200-215
95-110
110/43
340-430
60-30
225-240
115-130
Downloaded from
www.Manualslib.com
manuals search engine