262
Part Number 80-1479-3 7/10
S1800 Remote Air-cooled Condenser
All Remote Condenser Air-cooled with a Manufacture
Date Before 0910 (October 2009)
Characteristics may vary depending on operating conditions.
CYCLE TIMES
Freeze Time + Harvest Time = Total Cycle Time
24 HOUR ICE PRODUCTION
OPERATING PRESSURES
Air Temp.
Entering
Condenser
°F/°C
Freeze Time
Harvest
Time
1
1 Times in minutes
Water Temperature °F/°C
50/10
70/21
90/32
-20/-29 to 70/21
8.9-9.8
10.0-11.0
10.7-11.7
1 - 2.5
80/27
9.0-9.9
10.1-11.1
10.8-11.9
90/32
9.2-10.1
10.1-11.1
10.8-11.9
100/38
9.6-10.5
10.0-11.0
11.6-12.7
110/43
10.4-11.5
11.5-12.6
12.5-13.7
Air Temp. Entering
Condenser
°F/°C
Water Temperature °F/°C
12
1 Based on average ice slab weight of 13 - 14.125 lb
2 Ratings with JC1395 condenser
50/10
70/21
90/32
-20/-29 to 70/21
1800
1630
1540
80/27
1780
1620
1520
90/32
1750
1610
1520
100/38
1690
1630
1430
110/43
1570
1440
1340
Air Temp.
Entering
Condenser
°F/°C
Freeze Cycle
Harvest Cycle
Discharge
Pressure
PSIG
Suction
Pressure
PSIG
Discharge
Pressure
PSIG
Suction
Pressure
PSIG
1
1 Suction pressure drops gradually throughout the freeze cycle
-20/-29 to
50/10
220-250
44-26
110-170
65-85
70/21
240-280
50-28
115-180
70-90
80/27
245-290
50-28
115-180
70-90
90/32
250-300
52-28
120-195
70-90
100/38
260-340
60-28
125-210
70-90
110/43
295-390
60-30
125-220
80-100
Downloaded from
www.Manualslib.com
manuals search engine