100
Part N
umber 80-
1479-
3 7/10
Freeze Cycle
Suction Pressure
_______ ______ _____
1 minute Middle End
If suction pressure is High or Low refer to freeze cycle high or low suction pressure problem checklist
page 115 to eliminate problems and/or components not listed on this table before proceeding.
Suction pressure is
High
Suction pressure is
Low
or Normal
Suction pressure is
High
Suction pressure is
High
Wait 5 minutes into the
freeze cycle.
Compare temperatures of
compressor discharge line
and
both harvest valve
inlets.
The harvest valve inlet is
Hot
-and-
approaches the
temperature of a
Hot
compressor discharge
line.
The harvest valve inlet
is
Cool
enough to hold
hand on
-and-
the compressor
discharge line is
Hot.
The harvest valve inlet
is
Cool
enough to hold
hand on
-and-
the compressor
discharge line is
Cool
enough to hold hand on.
The harvest valve inlet
is
Cool
enough to hold
hand on
-and-
the compressor
discharge line is
Hot.