Part Number 80-1479-3 7/10
21
Installation
Location of Ice Machine
The location selected for the ice machine head section
must meet the following criteria. If any of these criteria
are not met, select another location.
• The location must be free of airborne and other
contaminants.
• Self contained air and water cooled - The air
temperature must be at least 35°F (1.6°C), but
must not exceed 110°F (43.4°C).
• Remote air cooled - The air temperature must be
at least -20°F (-29°C), but must not exceed 120°F
(49°C)
• Ice Making Water Inlet - Water Pressure must be
at least 20 psi (1.38 bar), but must not exceed 80
psi (5.52 bar).
• Condenser Water Inlet - Water Pressure must be
at least 20 psi (1.38 bar), but must not exceed
150 psi (10.34 bar). S3300W-HP units allow water
pressure up to 350 psig (24.13 bar)
.
• The location must not be near heat-generating
equipment or in direct sunlight and protected from
weather.
• The location must not obstruct air flow through or
around the ice machine. Refer to chart below for
clearance requirements.
• The ice machine must be protected if it will be
subjected to temperatures below 32°F (0°C).
Failure caused by exposure to freezing
temperatures is not covered by the warranty. See
“Removal from Service/Winterization”
!
Warning
PERSONAL INJURY POTENTIAL
Remove a ll i ce machi ne p anels before lifting a nd
installing.
Summary of Contents for S300
Page 2: ......
Page 20: ...20 Part Number 80 1479 3 7 10 This Page Intentionally Left Blank ...
Page 36: ...36 Part Number 80 1479 3 7 10 A B C D E ...
Page 45: ...Part Number 80 1479 3 7 10 45 A B C D E F G ...
Page 48: ...48 Part Number 80 1479 3 7 10 A A B C D E F G H I ...
Page 79: ...Part Number 80 1479 3 7 10 79 This Page Intentionally Left Blank ...
Page 80: ...80 Part Number 80 1479 3 7 10 This Page Intentionally Left Blank ...
Page 133: ...Part Number 80 1479 3 7 10 133 This Page Intentionally Left Blank ...
Page 134: ...134 Part Number 80 1479 3 7 10 This Page Intentionally Left Blank ...
Page 175: ...Part Number 80 1479 3 7 10 175 REMOTE RECOVERY EVACUATION CONNECTIONS ...
Page 184: ...184 Part Number 80 1479 3 7 10 SV1406 USING PINCH OFF TOOL ...
Page 189: ...Part Number 80 1479 3 7 10 189 This Page Intentionally Left Blank ...
Page 190: ...190 Part Number 80 1479 3 7 10 This Page Intentionally Left Blank ...
Page 296: ...296 Part Number 80 1479 3 7 10 This Page Intentionally Left Blank ...
Page 297: ...Part Number 80 1479 3 7 10 297 This Page Intentionally Left Blank ...
Page 298: ...298 Part Number 80 1479 3 7 10 ...
Page 299: ......