144
Part Number 80-1479-3 7/10
PROBLEM: WATER WILL NOT RUN INTO THE
SUMP TROUGH DURING THE FREEZE CYCLE
Step 1
Verify water is supplied to the ice
machine.Start a new Freeze sequence by moving the
ICE/OFF/CLEAN toggle switch to OFF, then back to
ICE.
Step 2
Wait until the freeze cycle starts
(approximately 45 seconds, the freeze cycle starts
when the compressor energizes).
Important
This rest art must be d one p rior to performing
diagnostic procedures. This assures the ice machine
is not in a freeze cycle wate r inlet valve safety shut-
off mode. You must complete the entire di agnostics
within 6 minutes of starting.
Summary of Contents for S300
Page 2: ......
Page 20: ...20 Part Number 80 1479 3 7 10 This Page Intentionally Left Blank ...
Page 36: ...36 Part Number 80 1479 3 7 10 A B C D E ...
Page 45: ...Part Number 80 1479 3 7 10 45 A B C D E F G ...
Page 48: ...48 Part Number 80 1479 3 7 10 A A B C D E F G H I ...
Page 79: ...Part Number 80 1479 3 7 10 79 This Page Intentionally Left Blank ...
Page 80: ...80 Part Number 80 1479 3 7 10 This Page Intentionally Left Blank ...
Page 133: ...Part Number 80 1479 3 7 10 133 This Page Intentionally Left Blank ...
Page 134: ...134 Part Number 80 1479 3 7 10 This Page Intentionally Left Blank ...
Page 175: ...Part Number 80 1479 3 7 10 175 REMOTE RECOVERY EVACUATION CONNECTIONS ...
Page 184: ...184 Part Number 80 1479 3 7 10 SV1406 USING PINCH OFF TOOL ...
Page 189: ...Part Number 80 1479 3 7 10 189 This Page Intentionally Left Blank ...
Page 190: ...190 Part Number 80 1479 3 7 10 This Page Intentionally Left Blank ...
Page 296: ...296 Part Number 80 1479 3 7 10 This Page Intentionally Left Blank ...
Page 297: ...Part Number 80 1479 3 7 10 297 This Page Intentionally Left Blank ...
Page 298: ...298 Part Number 80 1479 3 7 10 ...
Page 299: ......