Location of Condensing Unit
³
The air temperature must be at least -20°F (-28.9°C) but must
not exceed 130°F (54.4°C).
³
CVD675/CVD1185/CVD2075 Only
- The air temperature must
be at least -20°F (-28.9°C) but must not exceed 120°F (48.9°C).
³
CVD1486 Only
- The air temperature must be at least 50°F
(10°C) but must not exceed 110°F (43°C).
³
The location must not allow exhaust fan heat and/or grease to
enter the condenser.
³
The location must not obstruct airflow through or around the
condensing unit.