Head Section
Clearances
Top
5” (12.7 cm) is recommended for efficient operation and removal of top
cover/servicing.
Sides
5” (12.7 cm) is recommended for efficient operation and servicing.
There is no minimum clearance required.
Back
3” (7.6 cm) required when routing electrical inlet, water inlet and
refrigeration tubing out of the top of the unit.
5” (12.7 cm) required when routing all connections out the back.
³
The air temperature must be at least 35°F (1.6°C), but must not
exceed 110°F (43.4°C).
³
The location must be free of airborne and other contaminants.
³
The location must not be near heat-generating equipment or in
direct sunlight.
³
The location must not obstruct airflow through or around the ice
machine.
Summary of Contents for S model
Page 1: ...S Model QuietQube Ice Machines with CVD Technology Installation Training ...
Page 3: ...Typical QuietQube System Installation ...
Page 16: ...Inspection Remove carton inspect ice machine and condensing unit for shipping damage ...
Page 19: ...Model Serial Number Location Back of Ice Machine Inside of Ice Machine ...
Page 21: ...Warranty Registration Website Warranty Registration Form ...
Page 24: ...Ice Machine Wiring Install strain relief and proper wiring to ice machine head section ...
Page 29: ...Potable Water Supply Water Installation without filter Install union and shut off valve ...
Page 32: ...Lift Unit Trained qualified personnel are required for rigging and lifting ...
Page 41: ...Secure Line Set Secure Line Set as Needed Do not crush compress insulation ...
Page 49: ...Final Set Up ...
Page 52: ...S Model QuietQube Ice Machines with CVD Technology Installation Quiz Click Here to Launch ...