Section 6
Electrical System
6-32
NEW STYLE REMOTE
-
J450/J600/J800/J1000 - 1 PHASE
SV1582
L1
TB35
TB30
TB30
TB30
TB30
SEE SERIAL PLATE FOR VOLTAGE
L2 (N)
CAUTION: DISCONNECT POWER BEFORE
WORKING ON ELECTRICAL CIRCUITRY.
NOTE:
DIAGRAM SHOWN DURING FREEZE CYCLE.
TB32
(55)
(61)
(60)
(77)
(76)
(80)
(75)
(98)
(57)
(99)
(81)
(58)
(59)
(73)
(56)
(74)
TB31
TB37
3
1
2
4
TRANS.
FUSE (7A)
1C
1F
HIGH
PRESSUR
E CUT-
OUT
ICE THICKNESS PROBE
LOW D.C.
VOLTAGE
PLUG
CONNECTION NOT USED
BIN SWITCH
(62)
(63)
(64)
(65)
(66)
(66)
(67)
HARVEST LIGHT/
SAFETY LIMIT CODE LIGHT
BIN SWITCH LIGHT
(68)
(69)
(62)
VIEW FOR WIRING
66
67
68
69
62
TOGGLE SWITCH
CLEAN
OFF
ICE
←
←
←
←
INTERNAL
WORKING VIEW
HOT GAS
SOLENOID
DUMP
SOLENOID
WATER
PUMP
CONTACTOR
COIL
HPR
SOLENOID
(79)
(78)
(83)
(82)
LIQUID LINE
SOLENOID
(49)
(47)
COMPRESSOR
TB35
TB30
TB30
*OVERLOAD
CONTACTOR
CONTACTS
(48)
(42)
(51)
(52)
(53)
TB33
TB34
S
R
C
(50)
PTCR
L1
(46)
RUN CAPACITOR
R
R
(45)
TERMINATES AT
PIN CONNECTION
(F1)
(F2)
REMOTE
FAN MOTOR
RUN CAPACITOR
REMOTE
CONDENSER
LIGHT NOT USED
CLEAN LIGHT
Summary of Contents for J-1300
Page 1: ...J Model Service Manual 1997 Manitowoc Ice Inc Part No 83 5631 9 Rev A 8 97 Ice Machines ...
Page 10: ...Warranty Section 1 1 2 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 14: ...Section 2 Installation References 2 4 deflector is compatible with Manitowoc ice machines ...
Page 29: ...Section 2 Installation References 2 18 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 45: ...Section 3 Maintenance 3 16 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 105: ...Section 6 Electrical System 6 54 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 148: ...Section 7 Refrigeration System 7 43 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 164: ......