Section 7
Refrigeration System
7-58
7.
Is other special equipment required to service
HFC refrigerants?
No. Standard refrigeration equipment such as gauges,
hoses, recovery systems, vacuum pumps, etc., are
generally compatible with HFC refrigerants.
Consult your equipment manufacturer for specific
recommendations for converting existing
equipment to HFC usage. Once designated (and
calibrated, if needed) for HFC use, this equipment
should be used specifically with HFC refrigerants
only.
8.
Do I have to recover HFC refrigerants?
Yes. Like other refrigerants, government regulations
require recovering HFC refrigerants.
9.
Will R-404A or R-134A separate if there is a leak
in the system?
No. Like R-502, the degree of separation is too small
to detect.
10.
How do I charge a system with HFC refrigerant?
The same as R-502. Manitowoc recommends
charging only liquid refrigerant into the high side
of the system.
Summary of Contents for J-1300
Page 1: ...J Model Service Manual 1997 Manitowoc Ice Inc Part No 83 5631 9 Rev A 8 97 Ice Machines ...
Page 10: ...Warranty Section 1 1 2 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 14: ...Section 2 Installation References 2 4 deflector is compatible with Manitowoc ice machines ...
Page 29: ...Section 2 Installation References 2 18 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 45: ...Section 3 Maintenance 3 16 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 105: ...Section 6 Electrical System 6 54 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 148: ...Section 7 Refrigeration System 7 43 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 164: ......