Section 3
Maintenance
3-10
NOTE: During cleaning, do not stretch, damage or
remove the spring from the plunger. If it is removed,
slide the spring’s flared end into the plunger’s slotted
top opening until the spring contacts the plunger
spring stop.
5.
Remove the tubing from the dump valve by
twisting the clamps off.
6.
Remove the two screws securing the dump valve
and the mounting bracket.
Dump Valve Removal
WATER PUMP
WARNING
Disconnect the electric power to the ice machine at
the electric service switch box and turn off the
water supply.
1.
Disconnect the water pump power cord.
Water Pump Removal
2.
Disconnect the hose from the pump outlet.
3.
Loosen the two screws securing the pump
mounting bracket to the bulkhead.
4.
Lift the pump and bracket assembly off the
screws.
DRAIN
HOSE
SV1218
SV1209
VALVE
SHIELD
WATER
DUMP
VALVE
COIL
DO NOT
DISCONNECT
WIRES AT COIL
PUMP
OUTLET
WATER
PUMP
POWER
CORD
LOOSEN
SCREWS
Summary of Contents for J-1300
Page 1: ...J Model Service Manual 1997 Manitowoc Ice Inc Part No 83 5631 9 Rev A 8 97 Ice Machines ...
Page 10: ...Warranty Section 1 1 2 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 14: ...Section 2 Installation References 2 4 deflector is compatible with Manitowoc ice machines ...
Page 29: ...Section 2 Installation References 2 18 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 45: ...Section 3 Maintenance 3 16 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 105: ...Section 6 Electrical System 6 54 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 148: ...Section 7 Refrigeration System 7 43 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 164: ......