Section 3
Maintenance
3-11
ICE THICKNESS PROBE
1.
Compress the side of the ice thickness probe near
the top hinge pin and remove it from the bracket.
Ice Thickness Probe Removal
NOTE: At this stage, the ice thickness probe can
easily be cleaned. If complete removal is desired,
continue with step 2 below.
WARNING
Disconnect the electric power to the ice machine at
the electric service switch box.
2.
Disconnect the wire leads from the control board
inside the electrical control box.
WATER TROUGH
Water trough removal varies slightly by model. The
following procedure is typical.
1.
Remove the push-in screws holding the trough in
place.
Water Trough Removal
2.
Lower the right side of the trough into the bin.
3.
Disengage the left side of the trough from its
holding pegs and remove the trough.
DISCONNECT
WIRE LEADS
SV1212
SV1216
COMPRESS
HINGE PIN
TO REMOVE
ICE THICKNESS
PROBE
3. REMOVE
TROUGH
FROM PEGS
1. REMOVE
PUSH-IN
SCREWS
2. LOWER RIGHT
SIDE OF TROUGH
Summary of Contents for J-1300
Page 1: ...J Model Service Manual 1997 Manitowoc Ice Inc Part No 83 5631 9 Rev A 8 97 Ice Machines ...
Page 10: ...Warranty Section 1 1 2 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 14: ...Section 2 Installation References 2 4 deflector is compatible with Manitowoc ice machines ...
Page 29: ...Section 2 Installation References 2 18 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 45: ...Section 3 Maintenance 3 16 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 105: ...Section 6 Electrical System 6 54 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 148: ...Section 7 Refrigeration System 7 43 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 164: ......