![Manitowoc J-1300 Service Manual Download Page 109](http://html1.mh-extra.com/html/manitowoc/j-1300/j-1300_service-manual_700968109.webp)
Section 7
Refrigeration System
7-4
Remote Harvest Cycle (Models J450/J600/J800/J1000)
Harvest Cycle Refrigeration Sequence
Hot gas flows through the energized hot gas valve,
heating the evaporator. The hot gas valve is sized to
allow the proper amount of hot gas into the
evaporator. This specific hot gas valve sizing, along
with the harvest pressure regulating (H.P.R.) system,
assures proper heat transfer, without the hot gas
condensing to liquid and slugging the compressor.
The harvest pressure regulating (H.P.R.) valve helps
maintain the suction pressure during the harvest
cycle. (See “H.P.R. System” on page 7-26.)
SV1567
EVAPORATOR
HEAT
EXCHANGER
EXPANSION
VALVE
HOT GAS
SOLENOID VALVE
STRAINER
REMOTE
CONDENSER
RECEIVER
SERVICE VALVE
COMPRESSOR
DRIER
HIGH PRESSURE VAPOR
HIGH PRESSURE LIQUID
LOW PRESSURE VAPOR
LOW PRESSURE LIQUID
LIQUID LINE
SOLENOID
VALVE
RECEIVER
CHECK VALVE
CHECK VALVE
HARVEST
PRESSURE
REGULATING
VALVE
HARVEST
PRESSURE
REGULATING
SOLENOID VALVE
HEAD
PRESSURE
CONTROL
VALVE
C
B
R
Summary of Contents for J-1300
Page 1: ...J Model Service Manual 1997 Manitowoc Ice Inc Part No 83 5631 9 Rev A 8 97 Ice Machines ...
Page 10: ...Warranty Section 1 1 2 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 14: ...Section 2 Installation References 2 4 deflector is compatible with Manitowoc ice machines ...
Page 29: ...Section 2 Installation References 2 18 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 45: ...Section 3 Maintenance 3 16 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 105: ...Section 6 Electrical System 6 54 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 148: ...Section 7 Refrigeration System 7 43 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 164: ......