Section 6
Electrical System
6-3
Wiring Diagram Sequence of Operation
SELF-CONTAINED MODELS
Initial Start-Up or Start-Up After
Automatic Shut-Off
1. WATER PURGE
Before the compressor starts, the water
pump and water dump solenoid are
energized for 45 seconds to purge old
water from the ice machine. This ensures
that the ice-making cycle starts with fresh
water.
The hot gas valve(s) is also energized
during the water purge. In the case of an
initial refrigeration start-up, it stays on for
an additional 5 seconds (50 seconds
total).
(Old Style Control Board Shown)
Self-Contained Models
1. Water Purge
(45 Seconds)
Toggle Switch
ICE
Bin Switch
Closed
Control Board Relays
#1
Closed
Water Pump
ON
#2
Closed
Hot Gas Solenoid
ON
#3
Closed
Water Dump Valve
ON
#4
Open
Contactor Coil
OFF
Compressor
OFF
Condenser Fan Motor
OFF
Safety Controls
(Which could stop ice machine operation)
High Pressure Cut-Out
Closed
Main Fuse (On Control Board)
Closed
Transformer Fuse (On Control Board)
Closed
Thermistor Operation
OK
SV1559
L1
TB35
TB30
TB30
TB30
TB30
SEE SERIAL PLATE FOR VOLTAGE
L2 (N)
TB32
(55)
(61)
(60)
(77)
(80)
(76)
(75)
(98)
(99)
TB3
TB37
(59)
(73)
(74)
(56)
(58)
(57)
HOT GAS
SOLENOID
DUMP
SOLENOID
WATER
PUMP
TERMINATES AT
PIN CONNECTION
CONTACTOR COIL
TRANS.
FUSE
FUSE (7A)
ICE THICKNESS PROBE
DISCHARGE LINE THERMISTOR
3
1
2
4
1D
1C
1B
1A
BIN SWITCH
(62)
(63)
(65)
(64)
(66)
(66)
(67)
(62)
(69)
(68)
HARVEST LIGHT/
SAFETY CODE LIMIT LIGHT
BIN SWITCH LIGHT
ICE
OFF
CLEAN
TOGGLE SWITCH
VIEW FOR WIRING
62
66
69
67
68
HIGH
PRESSURE
CUTOUT
←
←
←
←
INTERNAL
WORKING VIEW
TB35
TB33
TB34
TB30
TB30
(49)
(47)
COMPRESSOR
RUN CAPACITOR
S
R
C
R
R
*OVERLOAD
PTCR
(46)
(45)
(50)
(42)
(48)
(52)
(85)
(86)
(53)
FAN CYCLE
CONTROL
L1
RUN CAPACITOR**
FAN MOTOR
(AIR-COOLED ONLY)
CONTACTOR
CONTACTS
Summary of Contents for J-1300
Page 1: ...J Model Service Manual 1997 Manitowoc Ice Inc Part No 83 5631 9 Rev A 8 97 Ice Machines ...
Page 10: ...Warranty Section 1 1 2 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 14: ...Section 2 Installation References 2 4 deflector is compatible with Manitowoc ice machines ...
Page 29: ...Section 2 Installation References 2 18 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 45: ...Section 3 Maintenance 3 16 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 105: ...Section 6 Electrical System 6 54 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 148: ...Section 7 Refrigeration System 7 43 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 164: ......