![Manitowoc IB1096YC Installation, Operation And Maintenance Manual Download Page 48](http://html.mh-extra.com/html/manitowoc/ib1096yc/ib1096yc_installation-operation-and-maintenance-manual_701394048.webp)
Customer Support
Section 5
48
SAFETY LIMIT FEATURE
In addition to the standard safety controls, such as the
high pressure cutout, your Manitowoc ice machine
features built-in safety limits which will stop the ice
machine if conditions arise which could cause a major
component failure.
Before calling for service, re-start the ice machine using
the following procedure:
1. Press the power button, the display reads “Off”.
Press the power button again and the display reads
“Making Ice”.
A. If the safety limit feature has stopped the ice
machine, it will restart after a short delay.
Proceed to step 2.
B. If the ice machine does not restart, see “Ice
machine does not operate” on the previous
page.
2. Allow the ice machine to run to determine if the
condition repeats.
A. If the ice machine stops again, the condition has
repeated. Call for service.
B. If the ice machine continues to run, the condition
has corrected itself. Allow the ice machine to
continue running.
Problem
Possible Cause
To Correct
Ice machine produces shallow or
incomplete cubes, or the ice fill pattern on
the evaporator is incomplete.
Ice thickness probe is out of adjustment.
Adjust the ice thickness probe.
(See Section 3)
Water is escaping the water trough.
Clean the dump valve (look for water at
drain outlet during freeze cycle), reinstall
water curtain, clean the ice machine to
stop water tracking out of trough area
Water inlet valve filter screen is dirty.
Remove the water inlet valve and clean
the filter screen. (See Section 4)
Water filtration is poor.
Replace the filter.
Hot incoming water.
Connect the ice machine to a cold water
supply. (See Section 2)
Water inlet valve is not working.
Clean or replace the water inlet valve.
(See Section 4)
Incorrect incoming water pressure.
Water pressure must be 20-80 psi
(137.9 - 551.5 kPA).
Ice machine head section is not level.
Level the ice machine head section.
(See Section 2)
Low ice capacity.
Water inlet valve filter screen is dirty.
Remove the water inlet valve and clean
the filter screen. (See Section 4)
Incoming water supply is shut off.
Open the water service valve.
Water inlet valve stuck open or leaking.
Replace the water inlet valve.
The condenser is dirty.
Clean the condenser. (See Section 4)
High air temperature entering condenser. Air temperature must not exceed 130°F
(54°C)
ICVD0695/ICVD1195/ICVD2095 - 120°F
(49°C)
The harvest assist air compressor is not
functioning.
Call for service.
Summary of Contents for IB1096YC
Page 26: ...Installation Section 2 26 Part Number 000007924 5 14 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 38: ...Operation Section 3 38 Part Number 000007924 5 14 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 51: ...Section 5 Customer Support Part Number 000007924 5 14 51 ...
Page 55: ...Table des matières suite 50 Part Number 000007924 5 14 ...
Page 73: ...Installation Section 2 68 Part Number 000007924 5 14 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 98: ...Section 5 Service clientèle Part Number 000007924 5 14 93 ...