![Manitowoc IB1096YC Installation, Operation And Maintenance Manual Download Page 42](http://html.mh-extra.com/html/manitowoc/ib1096yc/ib1096yc_installation-operation-and-maintenance-manual_701394042.webp)
Maintenance
Section 4
42
PARTS REMOVAL FOR CLEANING/SANITIZING
I0680C/I0870C/I0970C/I1070C/I1176C
A. Remove the water curtain
•
Gently flex the curtain in the center and remove it
from the right side.
•
Slide the left pin out.
B. Remove the ice thickness probe
•
Compress the hinge pin on the top of the ice
thickness probe.
•
Pivot the ice thickness probe to disengage one pin
then the other. The ice thickness probe can be
cleaned at this point without complete removal. If
complete removal is desired, disconnect the ice
thickness control wiring from the control board.
C. Remove the water trough
•
Depress tabs on right and left side of the water
trough.
•
Allow front of water trough to drop as you pull forward
to disengage the rear pins.
D. Remove the water level probe
•
Pull the water level probe straight down to
disengage.
•
Lower the water level probe until the wiring connector
is visible.
•
Disconnect the wire lead from the water level probe.
•
Remove the water level probe from the ice machine.
E. Remove the water distribution tube
NOTE: Distribution tube thumbscrews are retained to
prevent loss. Loosen thumbscrews but do not pull
thumbscrews out of distribution tube.
•
Loosen the two outer screws (do not remove screws
completely they are retained to prevent loss) and pull
forward on the distribution tube to release from slip
joint.
•
Disassemble distribution tube by loosening the two
(2) middle thumbscrews and dividing the distribution
tube into two pieces.
O f f
O n / O f f M o d e
[ ]
!
E
A
B
D
C
Summary of Contents for IB1096YC
Page 26: ...Installation Section 2 26 Part Number 000007924 5 14 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 38: ...Operation Section 3 38 Part Number 000007924 5 14 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 51: ...Section 5 Customer Support Part Number 000007924 5 14 51 ...
Page 55: ...Table des matières suite 50 Part Number 000007924 5 14 ...
Page 73: ...Installation Section 2 68 Part Number 000007924 5 14 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 98: ...Section 5 Service clientèle Part Number 000007924 5 14 93 ...