–178–
Q0800C/CVD875 SERIES REMOTE AIR COOLED
NOTE:
These characteristics may vary depending on
operating conditions.
CYCLE TIMES
24-HOUR ICE PRODUCTION
OPERATING PRESSURES
Freeze Time + Harvest Time = Cycle Time
Air Temp.
Entering
Condenser
°F/°C
Freeze Time
Harvest
Time
Water Temperature °F/°C
50/10.0
70/21.1
90/32.2
-20 to 70/
-29 to 21.1
9.4-10.8
10.5-12.1
11.4-13.1
.75-2.5
80/26.7
9.5-11.0
10.7-12.3
11.4-13.1
90/32.2
10.3-11.9
11.2-12.9
12.1-13.8
100/37.8
11.2-12.9
12.3-14.1
13.3-15.2
1
Times in minutes.
Air Temp.
Entering
Condenser
°F/°C
Water Temperature °F/°C
50/10.0
70/21.1
90/32.2
-20 to 70/
-29 to 21.1
760
690
640
80/26.7
750
680
640
90/32.2
700
650
610
100/37.8
650
600
560
1
Based on average ice slab weight of 5.75-6.50 lb.
2
Regular cube derate is 7%.
Air Temp.
Entering
Condenser
°F/°C
Freeze Cycle
Harvest Cycle
Discharge
Pressure
psig
Suction
Pressure
psig
Discharge
Pressure
psig
Suction
Pressure
psig
-20 to 50/
-29 to 10.0
260-215
46-22
140-185
70-95
70/21.1
270-220
40-23
150-190
70-100
80/26.7
285-225
47-24
155-195
80-95
90/32.2
295-235
52-25
165-200
85-100
100/37.8
340-260
56-26
180-210
85-112
110/43.3
385-300
60-28
195-230
90-115
Refer to page 176.